1999
DOI: 10.1034/j.1600-0501.1999.100601.x
|View full text |Cite
|
Sign up to set email alerts
|

Lack of integration of smooth titanium surfaces: a working hypothesis based on strains generated in the surrounding bone

Abstract: It has been observed that the polished neck of dental implants does not osseointegrate as do textured surfaces. Similar findings were reported in the orthopedic literature on artificial hip endoprostheses. In Dentistry, lack of osseointegration was attributed to increased pressure on the osseous bed during implant placement, establishment of a physiological "biologic width", stress shielding and lack of adequate biomechanical coupling between the load-bearing implant surface and the surrounding bone. Among the… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
140
1
17

Year Published

2007
2007
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 197 publications
(161 citation statements)
references
References 0 publications
3
140
1
17
Order By: Relevance
“…One thousand units of microstrain (1000 µε) correspond to the stretching or compression of 0.1% of the structure in question. 33,34 Nishioka et al 28 emphasizes that the CoCr alloy has been increasingly used in supported fixed dental prosthesis and supported implants for its high corrosion resistance, which ensures its biocompatibility.…”
Section: Discussionmentioning
confidence: 99%
“…One thousand units of microstrain (1000 µε) correspond to the stretching or compression of 0.1% of the structure in question. 33,34 Nishioka et al 28 emphasizes that the CoCr alloy has been increasingly used in supported fixed dental prosthesis and supported implants for its high corrosion resistance, which ensures its biocompatibility.…”
Section: Discussionmentioning
confidence: 99%
“…26 Four parallel, 11.5mm deep perforations were created at a distance of 14mm from each other (from center to center). These perforations were prepared in accordance with appropriate surgical protocol, excluding aseptic care, for the clinical use of four external hex cylinder implants (Master Screw 4.0X11.5; Conexão, São Paulo, Brazil).…”
Section: Methodsmentioning
confidence: 99%
“…O estímulo mecânico dentro de um limiar de carga pode resultar no desenvolvimento ósseo devido ao aumento da sua densidade e aposição. Porém, quando esse estímulo mecânico ultrapassa um limiar aceitável, resulta em microdanos por fadiga e, consequentemente, gera reabsorção óssea 4,8 .…”
Section: Introductionunclassified
“…Diferentes estudos in vitro, utilizando-se a técnica de extensometria e o poliuretano para simulação da estrutura óssea, verificaram o comportamento biomecânico em diferentes posições dos implantes e também em diferentes componentes para prótese sobre implantes [8][9][10] . A extensometria linear elétrica é uma proposta concreta para avaliar a distribuição de cargas estáticas ao redor de implantes [10][11][12] .…”
Section: Introductionunclassified