2001
DOI: 10.1016/s0584-8547(01)00265-8
|View full text |Cite
|
Sign up to set email alerts
|

Laser excited atomic fluorescence spectrometry — a review

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
31
0

Year Published

2002
2002
2012
2012

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 55 publications
(31 citation statements)
references
References 105 publications
0
31
0
Order By: Relevance
“…It has already been associated with several other techniques and reviews on the subject can be found in the literature. 21 The LIBS-LIF approach consists of generating an ablation plasma using a first laser, then re-excite the atoms of the element of interest using a second laser tuned to a specific wavelength, corresponding to a strong absorption line. This hyphenated approach has been studied for the detection of trace elements in solids, [22][23][24][25][26][27][28][29][30] liquids [31][32][33][34] and aerosols, 35 in ambient air or in various controlled atmospheres.…”
Section: -20mentioning
confidence: 99%
“…It has already been associated with several other techniques and reviews on the subject can be found in the literature. 21 The LIBS-LIF approach consists of generating an ablation plasma using a first laser, then re-excite the atoms of the element of interest using a second laser tuned to a specific wavelength, corresponding to a strong absorption line. This hyphenated approach has been studied for the detection of trace elements in solids, [22][23][24][25][26][27][28][29][30] liquids [31][32][33][34] and aerosols, 35 in ambient air or in various controlled atmospheres.…”
Section: -20mentioning
confidence: 99%
“…The limits of detection (3σ) found under these conditions were 15 times higher than the lowest instrumental LOD reported in ref. [2]. This may be caused by the low 10-Hz repetition rate, the non-specific absorption, and the intricate chemical composition of the gas phase during the atomization process, which may lead to quenching phenomena, especially at high temperature.…”
Section: Data Processing and Detection Limitmentioning
confidence: 99%
“…Electrothermal atomization-laser-excited atomic fluorescence (ETA-LEAF) is among the most sensitive methods for direct metal analysis [2] and certainly the most sensitive one for lead determination, since metal contents as low as 0.2 fg (1 attomol) can theoretically be detected [3,4]. Actually, depending on the matrix and injection volume, detection limits (3σ) within 50 pg L -1 [3] and 1 ng L -1 [5,6,7,8,9] have been published.…”
Section: Introductionmentioning
confidence: 99%
“…One promising avenue for improving the sensitivity of LIBS consists in using the LIBS-LIFS approach (LIBS combined with Laser-Induced Fluorescence Spectroscopy) [4]. It has already been shown for various trace elements that this approach can improve notably the LoD [5][6][7][8][9][10].…”
Section: Introductionmentioning
confidence: 99%