2011
DOI: 10.1016/j.renene.2010.08.027
|View full text |Cite
|
Sign up to set email alerts
|

Limitations of fixed pitch Darrieus hydrokinetic turbines and the challenge of variable pitch

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
30
0
3

Year Published

2011
2011
2022
2022

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 110 publications
(34 citation statements)
references
References 4 publications
1
30
0
3
Order By: Relevance
“…Increased of rotation at the same flow rate using passive variable-pitch have a larger trend when compared with the fixed-pitch. This is consistent with many researchers finding that start of rotating capabilities is one disadvantages of vertical axis turbine types [2,11]. According to rotation produced in Table 1, TSR values is determined and shown in Table 2.…”
Section: Vertical-axis Turbine Testsupporting
confidence: 87%
“…Increased of rotation at the same flow rate using passive variable-pitch have a larger trend when compared with the fixed-pitch. This is consistent with many researchers finding that start of rotating capabilities is one disadvantages of vertical axis turbine types [2,11]. According to rotation produced in Table 1, TSR values is determined and shown in Table 2.…”
Section: Vertical-axis Turbine Testsupporting
confidence: 87%
“…Although relatively easy and simple to build, one of the drawbacks of this design is that at low speeds, straight blades can suffer wildly varying angle of attack (Kirke and Lazauskas 2011). This makes fixed pitch straight-bladed devices liable to stall, reduces overall device performance, hampers their ability to self-start and imposes additional stresses on the device in the form of rapidly fluctuating torque pulsations.…”
Section: Cross-flow Turbinesmentioning
confidence: 99%
“…In principle, it is possible to minimise these issues through the use of a pitch-control system (Kirke and Lazauskas 2011). Active pitch-control systems, where blade pitch is forced to follow a predetermined regime, are mechanically complex, however, the designs of passive pitch-control systems, where the forces acting on the blades control the pitch, are of dubious effectiveness.…”
Section: Cross-flow Turbinesmentioning
confidence: 99%
See 1 more Smart Citation
“…VAWTs are usually stall regulated due to the complexities with pitch regulation [9,10]. Therefore, the effect of dynamic stall is very important for the operation of VAWTs.…”
Section: Introductionmentioning
confidence: 99%