2004
DOI: 10.1016/s1056-8727(03)00075-8
|View full text |Cite
|
Sign up to set email alerts
|

Lipids and lipoprotein(a) concentrations in Tunisian type 2 diabetic patients

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

5
20
0

Year Published

2005
2005
2015
2015

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 39 publications
(25 citation statements)
references
References 28 publications
5
20
0
Order By: Relevance
“…Biochemical measurements were carried out according to validated methods. Serum glucose concentration was determined using an enzymatic kit (Glucose oxidase, Randox, Antrim, UK), glycosylated hemoglobin (HbA1c) by an exchange microcolumn chromatographic procedure (Biosystems, Barcelona, Spain), total cholesterol and triglycerides by enzymatic methods using Randox reagents, and LDL and HDL cholesterol were determined as described by Smaoui et al 9 Serum ACE activity was determined in AMI patients who did not take ACE-inhibitors or angiotensin II receptor antagonists. The serum was stored at -20°C until assay.…”
Section: Biochemical Measurementsmentioning
confidence: 99%
“…Biochemical measurements were carried out according to validated methods. Serum glucose concentration was determined using an enzymatic kit (Glucose oxidase, Randox, Antrim, UK), glycosylated hemoglobin (HbA1c) by an exchange microcolumn chromatographic procedure (Biosystems, Barcelona, Spain), total cholesterol and triglycerides by enzymatic methods using Randox reagents, and LDL and HDL cholesterol were determined as described by Smaoui et al 9 Serum ACE activity was determined in AMI patients who did not take ACE-inhibitors or angiotensin II receptor antagonists. The serum was stored at -20°C until assay.…”
Section: Biochemical Measurementsmentioning
confidence: 99%
“…Plasma glucose concentration was evaluated using an enzymatic kit (glucose oxidase, Randox, Antrim, UK), glycosylated hemoglobin (HbA1c) by an exchange microcolumn chromatographic procedure (Biosystems, Barcelona, Spain), total cholesterol and triglycerides by enzymatic methods using Randox reagents and LDL and HDL cholesterol determined as described by Smaoui et al [22].…”
Section: Laboratory Proceduresmentioning
confidence: 99%
“…There is a large body of evidence linking dyslipidaemia and cardiovascular risk in patients with diabetes against quite few negative reports (Vlajinac et al 1992;Roselli della Rovere et al 2003) on this issue. Cross-sectional studies have found positive associations of atherosclerotic vascular disease with TC (Ronnemaa et al 1989;Jurado et al 2009), LDL-C (Reckless et al 1978;Agarwal et al 2009;Jurado et al 2009), non-HDL-C (Jurado et al 2009), TG (Santen et al 1972;Ronnemaa et al 1989;Gomes et al 2009), apoB (Ronnemaa et al 1989) and Lp(a) (Mohan et al 1998;Murakami et al 1998;Smaoui et al 2004), but inverse associations with HDL-C (Reckless et al 1978;Ronnemaa et al 1989;Smaoui et al 2004;Grant and Meigs 2007;Gomes et al 2009;Jurado et al 2009) and apoA-I (Seviour et al 1988;Ronnemaa et al 1989). Prospective data have provided with further evidence.…”
Section: Ethnic Differences In Lipid Profiles In General Populationsmentioning
confidence: 99%