1978
DOI: 10.1021/ac50030a017
|View full text |Cite
|
Sign up to set email alerts
|

Liquid chromatography detector based on single and twin electrode thin-layer electrochemistry: application to the determination of catecholamines in blood plasma

Abstract: An electrochemical detector lor liquid chromatography was designed and constructed, based upon thin-layer cells with working electrodes prepared from a mixture ot Ceresin wax and graphite powder In a ratio of 1:1.3 by weight. Both twin electrode steady-state amperometry (four-electrode configuration) and simple thin-layer hydrodynamic amperometry (three-electrode configuration) were examined. A comparison of the four-electrode system with the three-electrode method showed the former to be slightly more sensiti… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
19
0

Year Published

1982
1982
2015
2015

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 97 publications
(19 citation statements)
references
References 23 publications
0
19
0
Order By: Relevance
“…Dopamine and 5-HT were measured either according to the method of Keller et al (1976) as modified in this laboratory (Lucot et al, 1981), or according to Kotake et al (1985). Norepinephrine was measured using the method of Fenn et al (1978). The brain regions sampled and the amines assayed varied from experiment to experiment (Tables 2-6).…”
Section: " Determination Of Amine Levelsmentioning
confidence: 99%
“…Dopamine and 5-HT were measured either according to the method of Keller et al (1976) as modified in this laboratory (Lucot et al, 1981), or according to Kotake et al (1985). Norepinephrine was measured using the method of Fenn et al (1978). The brain regions sampled and the amines assayed varied from experiment to experiment (Tables 2-6).…”
Section: " Determination Of Amine Levelsmentioning
confidence: 99%
“…LC with electrochemical detection offers a sensitive method for measuring human plasma catecholamines that is simpler than the existing radioenzymatic assays (Hallman et at., 1978;Fenn et at., 1978;Hjemdahl et at., 1979;Fig. 6).…”
Section: Measurement Of Plasma Catecholamines Indoleamines and Drugsmentioning
confidence: 99%
“…Some electrochemical reactions are chemically irreversible and some are chemically reversible, and therefore, the dual electrode arrangement can eliminate the response to irreversible substances while maintaining the response to reversible substances [6,7] . On the other hand, dual electrodes facing each other is a geometry suitable for enhancing a signal because the electrochemically reversible analyte oxidized at one electrode can be reduced at the other [8]. Since this redox cycling continues, the signal is enhanced.…”
Section: Introductionmentioning
confidence: 99%