1997
DOI: 10.1016/s0196-8904(96)00108-2
|View full text |Cite
|
Sign up to set email alerts
|

Load frequency control of isolated wind diesel hybrid power systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
60
0

Year Published

2008
2008
2022
2022

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 110 publications
(61 citation statements)
references
References 7 publications
1
60
0
Order By: Relevance
“…Unbalanced reactive power operation results in voltage variation. Reactive power control by using VAR compensator (SVC) [22], or static-synchronous compensator (STAT-COM) [23], work well but they may add harmonics to the electrical network while compensating reactive power continuously and may not be able to provide the adequate amount of reactive power under varying input and/or load conditions such as wind energy sources which fluctuate highly in nature. On the other hand, several techniques to improve the power factor of induction machines have been suggested, namely, capacitors, capacitors with switched inductor, and solid-state power factor controllers [10,11].…”
Section: Induction Generator For Wind Powermentioning
confidence: 99%
“…Unbalanced reactive power operation results in voltage variation. Reactive power control by using VAR compensator (SVC) [22], or static-synchronous compensator (STAT-COM) [23], work well but they may add harmonics to the electrical network while compensating reactive power continuously and may not be able to provide the adequate amount of reactive power under varying input and/or load conditions such as wind energy sources which fluctuate highly in nature. On the other hand, several techniques to improve the power factor of induction machines have been suggested, namely, capacitors, capacitors with switched inductor, and solid-state power factor controllers [10,11].…”
Section: Induction Generator For Wind Powermentioning
confidence: 99%
“…In previous studies have discussed many frequency control on microhydro, such as [1], [2], [3,4]. Of the several studies, micro-hydro control is still not optimal because it is still based on conventional PID.…”
Section: Introductionmentioning
confidence: 99%
“…A wind-diesel model and its transient behavior are discussed in [5]. In [6], a strategy to control frequency variations in this kind of systems is proposed.…”
Section: Introductionmentioning
confidence: 99%