1974
DOI: 10.1111/j.1365-2818.1974.tb03932.x
|View full text |Cite
|
Sign up to set email alerts
|

Lung fixation by perfusion—a simple method to control the pressure in the perfusion circuit

Abstract: SUMMARY A simple method which maintains the hydraulic pressure at a constant level during fixation of organs by perfusion is described. This is obtained by means of a glass tube interposed between a peristaltic pump and the organ to be perfused, the specially designed glass tube acting as a safety valve. The efficiency of the system is tested by electromagnetic pressure recording.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

1974
1974
1983
1983

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 5 publications
0
3
0
Order By: Relevance
“…The lungs of 20 Wistar rats (150 g) deeply anesthetized by intraperitoneal (i .p .) Nembutal (17 mg/100 g) were fixed by perfusion (10)(11)(12) ; 6 other rat lungs were fixed by conventional intratracheal instillation. We used 2% glutaraldehyde adjusted with phosphate buffer and saccharose to pH 7 .4 and 350 mosmol .…”
Section: Electron Microscopymentioning
confidence: 99%
“…The lungs of 20 Wistar rats (150 g) deeply anesthetized by intraperitoneal (i .p .) Nembutal (17 mg/100 g) were fixed by perfusion (10)(11)(12) ; 6 other rat lungs were fixed by conventional intratracheal instillation. We used 2% glutaraldehyde adjusted with phosphate buffer and saccharose to pH 7 .4 and 350 mosmol .…”
Section: Electron Microscopymentioning
confidence: 99%
“…During the past few years, elegant studies which correlate pulmonary structural configurations with known functional conditions have been published by the Swiss scientists (Assimacopou-10s et al, 1976;Bachofen et al, 1979;Gil et al, 1979;Gil and Weibel, 1971). However, a disadvantage for many workers in lung research in adopting their techniques is the requirement for rather sophisticated instrumentation and expensive equipment (Assimacopoulos and Kapanci, 1973;Gil and Weibel, 1971). The use of air from a n air inlet valve, which should be available in any laboratory, obviates the need for a peristaltic pump for perfusate delivery.…”
Section: Discussionmentioning
confidence: 99%
“…The lungs were fixed in situ by perfusion ac cording to the method described elsewhere [2). The perfusion pressure was adjusted to 35 cm H20 and the intratracheal pressure to 12 cm H ,0.…”
Section: Methodsmentioning
confidence: 99%