2017
DOI: 10.1016/j.chroma.2017.05.009
|View full text |Cite
|
Sign up to set email alerts
|

Magnetically assisted matrix solid phase dispersion for extraction of parabens from breast milks

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
28
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 58 publications
(28 citation statements)
references
References 35 publications
0
28
0
Order By: Relevance
“…The content of THF in the bulk solution influences SUPRASs composition and structure and, consequently, it could affect extraction efficiency [25]. SUPRASs were prepared from a constant concentration of 1-decanol (2.4%, v/v) and varying percentages of THF (10,15,20, and 25%, v/v). Here, the total volume of the bulk solution, which the extraction device was able to take up, was considered to be 5 mL.…”
Section: Selection Of Supras-me Conditionsmentioning
confidence: 99%
See 1 more Smart Citation
“…The content of THF in the bulk solution influences SUPRASs composition and structure and, consequently, it could affect extraction efficiency [25]. SUPRASs were prepared from a constant concentration of 1-decanol (2.4%, v/v) and varying percentages of THF (10,15,20, and 25%, v/v). Here, the total volume of the bulk solution, which the extraction device was able to take up, was considered to be 5 mL.…”
Section: Selection Of Supras-me Conditionsmentioning
confidence: 99%
“…A variety of analytical methods for determining parabens in both solid and liquid samples have been reported to date by LC [4][5][6][7][8][9][10], GC [11][12][13][14][15], and CE [16,17]. LC techniques are more commonly used for parabens since GC methods usually require a prior derivatization of the compounds [5].…”
Section: Introductionmentioning
confidence: 99%
“…A study from Turkey 30 detected parabens in milk samples in a concentration range from 300 to 6000 ng mL -1 . In Iran, 36,40 parabens levels were determined in a range from 0.792 to 1.180 ng mL -1 and 51.2 to 3270.3 ng mL -1 , respectively. Fisher et al 41 determined parabens levels in milk samples in a range from 0.0023 to 16.325 ng mL -1 .…”
Section: Concentration Of Parabens In Breast Milk Samples From Voluntmentioning
confidence: 99%
“…Fotouhi et al [55] applied magnetically assisted matrix solid-phase dispersion (MA-MSPD) to extract and determine by LC-UV and LC-MS/MS residues of parabens in breast milk. A new material was prepared reacting Fe ions and GO in aqueous media with subsequent copolymerization of indolethiophene on GO (Fe 3 O 4 -GO) to bring up magnetic characteristic to the sorbent phase, termed magnetic graphene oxide bounded with indole-thiophene polymer.…”
Section: Other Applicationsmentioning
confidence: 99%