2001
DOI: 10.1109/19.918168
|View full text |Cite
|
Sign up to set email alerts
|

Maintenance and dissemination of the magnetic field unit at PTB

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2004
2004
2021
2021

Publication Types

Select...
3
3
2

Relationship

0
8

Authors

Journals

citations
Cited by 20 publications
(12 citation statements)
references
References 6 publications
0
12
0
Order By: Relevance
“…The water quality according to EN ISO 3696 [11] is better than grade 2, showing a conductivity of about 0.3 lS/cm at 25°C. The measurements were performed using an existing NMR free precession measuring system built for the dissemination of the unit Tesla of the DC magnetic flux density [12]. The polarization field of 5.5 mT, generated by a Helmholtz coil with 100 mm inner diameter and a coil constant of 6 mT/A, was applied for 5 s. The detection field was generated by using a Helmholtz coil in combination with a three axial coil system according to Braunbek [13], which compensates the Earth's field down to a value of about 10 nT.…”
Section: Measurements and Resultsmentioning
confidence: 99%
“…The water quality according to EN ISO 3696 [11] is better than grade 2, showing a conductivity of about 0.3 lS/cm at 25°C. The measurements were performed using an existing NMR free precession measuring system built for the dissemination of the unit Tesla of the DC magnetic flux density [12]. The polarization field of 5.5 mT, generated by a Helmholtz coil with 100 mm inner diameter and a coil constant of 6 mT/A, was applied for 5 s. The detection field was generated by using a Helmholtz coil in combination with a three axial coil system according to Braunbek [13], which compensates the Earth's field down to a value of about 10 nT.…”
Section: Measurements and Resultsmentioning
confidence: 99%
“…Note that the error of meters 2,4,7,9,18,22,23,31, and 34 at 10 kHz is considerably larger than the average error. Figs.…”
Section: Evaluation Of Meters With Frequency Ranges Above 10 Khzmentioning
confidence: 90%
“…Although the standards [12,14] recommend that calibrations should be performed at frequencies far beyond from the resonance frequency of the coil system, they do not propose a specific frequency limit or correction procedure. Nevertheless, there are standard procedures to find the correction function of each coil system [22] that could improve the frequency performance of the meters.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The DC magnetic field can be precisely decided and realized using nuclear magnetic resonance (NMR) system [4][5] and the AC magnetic field can be expanded from this precise DC magnetic field standard [4]. However, it is known that it is difficult to realize the AC magnetic field at the frequency bands more than dozens of kHz when the AC magnetic field is expanded from the DC magnetic field.…”
Section: System For Ac Magnetometer Calibration In Nmijmentioning
confidence: 99%