2019
DOI: 10.1016/j.jksus.2019.01.009
|View full text |Cite
|
Sign up to set email alerts
|

Mathematical modelling of a tidal power station with diesel and wind units

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 21 publications
0
5
0
Order By: Relevance
“…The reactive power fluctuated to about zero (1.865 × 10 −7 VAR), whereas the active power was 2.5 MW. Between t = 0 and t = 0.3 s, the active power signal overshoots were 14.557%, while between t = 0.3 and t = 0.4 s, the value fell short by approximately 1.998% at time t = 0.6 s according to Equation (18) presented in Energies Standard 2021, volume 14 (page 688). Figure 15 shows the phase-to-ground voltage wave, which had a total harmonic tortion of 141.38%, and the phase current signal had a total harmonic distortion of 13.5 The total harmonic distortions for current and voltage illustrated in Figure 15a,b creased by 0.07% and 0.12%, respectively.…”
Section: Case Studiesmentioning
confidence: 99%
See 1 more Smart Citation
“…The reactive power fluctuated to about zero (1.865 × 10 −7 VAR), whereas the active power was 2.5 MW. Between t = 0 and t = 0.3 s, the active power signal overshoots were 14.557%, while between t = 0.3 and t = 0.4 s, the value fell short by approximately 1.998% at time t = 0.6 s according to Equation (18) presented in Energies Standard 2021, volume 14 (page 688). Figure 15 shows the phase-to-ground voltage wave, which had a total harmonic tortion of 141.38%, and the phase current signal had a total harmonic distortion of 13.5 The total harmonic distortions for current and voltage illustrated in Figure 15a,b creased by 0.07% and 0.12%, respectively.…”
Section: Case Studiesmentioning
confidence: 99%
“…The modelling of tidal power plant components is the subject of numerous scholarly articles. However, extensive research has not been conducted on the use of filters in tidal generation systems [18]. Several filter design methodologies and applications have also been described in the literature, although only for grid-connected inverters for wind and solar systems [19].…”
Section: Introductionmentioning
confidence: 99%
“…Studies [15,16] suggest a method of forecasting and managing a ship's power plant using a model of this plant with a permanent model structure. However, when the power plant's operational mode changes, the structure of the system changes as well, which affects the system model and modeling results.…”
Section: An Improvement Of the Control System Implied The Integration Of A Modeling Unit And A Decision Support Unit Into Its Structure Tmentioning
confidence: 99%
“…However, the inherent randomness and intermittence of offshore wind energy inevitably lead to large power fluctuations in the terminal power system, resulting in increased maintenance and balance costs [11][12][13]. To address this challenge, various multi-energy complementary power generation schemes have been proposed that integrate offshore wind energy with other ocean energy sources [14][15][16][17][18][19]. Among these, the combined wave-wind power generation system is considered to be the best option due to its economic efficiency and technical feasibility [20][21][22][23].…”
Section: Introductionmentioning
confidence: 99%