2014
DOI: 10.1590/0104-6632.20140313s00002623
|View full text |Cite
|
Sign up to set email alerts
|

Measurement and correlation of isobaric vapor-liquid equilibrium for the binary system of cyclopentane and tetrahydrofuran

Abstract: -Isobaric vapor-liquid equilibrium (VLE) data for the cyclopentane and tetrahydrofuran (THF) system were measured at 101.3 kPa by using an equilibrium still. Thermodynamic consistency of the experimental data was confirmed by means of the Herington method. The experimental data were correlated and calculated by the Margules, Van Laar and Wilson activity-coefficient models, respectively. The Wilson and Van Laar activity-coefficient models are better than the Margules activity-coefficient model based on the aver… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 11 publications
0
3
0
Order By: Relevance
“…The comparison of experimental and calculated data is presented in Table and Figure along with their deviations. The results indicate that the data were in good agreement, giving an average absolute deviation ( AAD ) of not more than 1.0%, calculated using eqs and A D = [ T i s a t e x p T i s a t c a l c ] italicAAD 0.25em T = 1 n i = 1 n | T exp T calc | …”
Section: Resultsmentioning
confidence: 76%
See 1 more Smart Citation
“…The comparison of experimental and calculated data is presented in Table and Figure along with their deviations. The results indicate that the data were in good agreement, giving an average absolute deviation ( AAD ) of not more than 1.0%, calculated using eqs and A D = [ T i s a t e x p T i s a t c a l c ] italicAAD 0.25em T = 1 n i = 1 n | T exp T calc | …”
Section: Resultsmentioning
confidence: 76%
“…The average absolute deviation ( AAD ) of the temperature and vapor fraction between experimental and correlated data, based on refs , was used to evaluate the accuracy of the results using eqs and , respectively. italicAAD 0.25em T = 1 italicNT i = 1 NT | T i exp T i calc | italicAAD 0.25em y = 1 italicNy i = 1 Ny | y i exp y i calc | where a ij , a ji , b ij , b ji , u ij , and u ji were the binary parameters of each model (Wilson, NRTL, and UNIQUAC, respectively).…”
Section: Resultsmentioning
confidence: 99%
“…To ensure the reliability of the measured VLE data, the thermodynamic consistency test was performed by the Herington and van Ness method. The non-random two-liquid (NRTL) (Renon and Prausnitz, 1968;Liu et al, 2019), Wilson (Wilson, 1964;Li, 2014), and the universal quasi-chemical (UNIQUAC) (Abrams and Prausnitz, 1975) activity coefficient models were used to correlate the experimental VLE data and the binary interaction parameters for the three models were regressed. In addition, the calculation of the excess Gibbs energy for the three systems from the VLE data was listed.…”
Section: Introductionmentioning