2001
DOI: 10.1002/fact.1001
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of atmospheric formaldehyde with a diffusion scrubber and light‐emitting diode–liquid‐core waveguide based fluorometry

Abstract: A new automated instrument for the near-realtime measurement of atmospheric formaldehyde is described. The chemistry involves the cyclization reaction of formaldehyde with 1,3-cyclohexanedione (CHD) in the presence of ammonium ions to form a fluorescent dihydropyridine derivative. A GaN-based light-emitting diode (LED) emitting in the near UV was used as the excitation source in a miniature flowthrough fluorescence detector based on a transversely illuminated liquid-core waveguide. The instrument is configured… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
56
0

Year Published

2003
2003
2011
2011

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 54 publications
(56 citation statements)
references
References 50 publications
0
56
0
Order By: Relevance
“…A commercial, wet-chemical instrument (Methanalyser, Alpha Omega Power Technologies, Model MA-100, Albuquerque, New Mexico, USA) was deployed for HCHO measurements (Li et al, 2001;Fan and Dasgupta, 1994). The instrument consists of a Nafion-membrane diffusion scrubber integrated with an automated, liquid reactor.…”
Section: Hantzsch Ma-100 (Iup-ub)mentioning
confidence: 99%
“…A commercial, wet-chemical instrument (Methanalyser, Alpha Omega Power Technologies, Model MA-100, Albuquerque, New Mexico, USA) was deployed for HCHO measurements (Li et al, 2001;Fan and Dasgupta, 1994). The instrument consists of a Nafion-membrane diffusion scrubber integrated with an automated, liquid reactor.…”
Section: Hantzsch Ma-100 (Iup-ub)mentioning
confidence: 99%
“…This detector has been used for fluorometry 67,68 and chemiluminescence measurements 69 of H2O2 and hydroxymethyl hydroperoxide, and fluorometry of HCHO. 70,71 LODs of 10 -30 pptv have been obtained for continuous or near real-time measurements.…”
Section: ·5 Detection Methods For Collected Species Ii: Miniaturementioning
confidence: 99%
“…71 In Japan, there are similar projects. Background levels of acidic atmospheric gases were measured at Oki and Rishiri islands, and daily fluctuations of sub-ppbv levels were obtained.…”
Section: ·6 Applications For Atmospheric Trace Gas Analysismentioning
confidence: 99%
“…Intercomparisons among various formaldehyde detection methods have also been carried out in Gilpin et al (1997) and Cárdenas et al (2000). Although formaldehyde can also be a challenge to analyse, over the last 20 years high quality measurements of formaldehyde have been established using wet-chemical techniques Dasgupta, 1986, 1987;Fan and Dasgupta, 1994;Heikes et al, 1996;Dasgupta et al, 1988Dasgupta et al, , 1998Dasgupta et al, , 1999Li et al, 2001). Such instruments are relatively inexpensive, have a detection limit in the mid-ppt (parts per trillion) range, are commercially available, run essentially continuously, and are highly selective for formaldehyde.…”
Section: Introductionmentioning
confidence: 99%