2000
DOI: 10.1093/clinchem/46.10.1643
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of Transcobalamin by ELISA

Abstract: Background: Transcobalamin is essential for the cellular internalization of cobalamin. Methods to quantify the unsaturated protein are available, but few attempts have been made to develop methods to quantify the sum of unsaturated and cobalamin saturated transcobalamin. Methods: γ-Globulins from two polyclonal rabbit antibodies against recombinant human transcobalamin were used as capture and detection antibodies, and recombinant human transcobalamin was used as calibrator in an ELISA design. … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
17
0
1

Year Published

2005
2005
2022
2022

Publication Types

Select...
4
4

Relationship

1
7

Authors

Journals

citations
Cited by 74 publications
(19 citation statements)
references
References 19 publications
1
17
0
1
Order By: Relevance
“…Our data challenge the value of judging an early B12 status by total B12 measurements in these patients and also challenge whether B12 status remains normal up to 6 month after surgery. Total B12 roughly represents 20% B12 bound to TC (holoTC) and 80% bound to haptocorrin [14,19]. Only B12 bound to TC is available for the tissues, and is thus called 'active B12'.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Our data challenge the value of judging an early B12 status by total B12 measurements in these patients and also challenge whether B12 status remains normal up to 6 month after surgery. Total B12 roughly represents 20% B12 bound to TC (holoTC) and 80% bound to haptocorrin [14,19]. Only B12 bound to TC is available for the tissues, and is thus called 'active B12'.…”
Section: Discussionmentioning
confidence: 99%
“…Plasma/serum, was collected and stored at À80 C until further analysis of B12 (ADVIA Centaur CP immunoassay System, Siemens Healthcare Diagnostics) and holotranscobalamin (holoTC) (in-house method; CV 7e8%, ref. [13,14]). All B12 and holoTC analyses on samples from the same patient were performed together after the patients had concluded the study.…”
Section: Sample Collection and Analysismentioning
confidence: 99%
“…TotalTC was measured by an in-house sandwich ELISA with a total imprecision of 4%-6% and an intra-assay imprecision of 3% (12). HoloTC was measured by the TC-ELISA after removal of the apoTC with cobalamin-coated beads (13).…”
Section: Biochemical Measurementsmentioning
confidence: 99%
“…Serum total transcobalamin (totalTC) and cobalamin saturated transcobalamin (holoTC) were measured by ELISA (Nexo et al 2000(Nexo et al , 2002 employing an automated ELISA analyser (BEP-2000, Dade Behring, Germany), and serum TC saturation was calculated as holoTC/totalTC. Analytical imprecision was 5% for totalTC and 8% for holoTC.…”
Section: Laboratory Investigationsmentioning
confidence: 99%