2003
DOI: 10.1016/s1010-6030(03)00062-5
|View full text |Cite
|
Sign up to set email alerts
|

Measurements of molecular absorption spectra with the SCIAMACHY pre-flight model: instrument characterization and reference data for atmospheric remote-sensing in the 230–2380 nm region

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

37
613
3
8

Year Published

2007
2007
2017
2017

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 674 publications
(661 citation statements)
references
References 23 publications
37
613
3
8
Order By: Relevance
“…Some aspects pertaining to the retrievals are characteristic to each instrument, and we give here a short overview of the main differences. [Bogumil et al, 2003] and OMI [Vandaele et al, 1998] but the differences are less than 2% at all temperatures, affecting differences in the temperature correction in the SCIAMACHY and OMI retrievals by at most 2%. We do not expect significant differences between SCIAMACHY and OMI slant columns from the fitting differences in Table 2 or from the temperature correction.…”
Section: Introductionmentioning
confidence: 92%
“…Some aspects pertaining to the retrievals are characteristic to each instrument, and we give here a short overview of the main differences. [Bogumil et al, 2003] and OMI [Vandaele et al, 1998] but the differences are less than 2% at all temperatures, affecting differences in the temperature correction in the SCIAMACHY and OMI retrievals by at most 2%. We do not expect significant differences between SCIAMACHY and OMI slant columns from the fitting differences in Table 2 or from the temperature correction.…”
Section: Introductionmentioning
confidence: 92%
“…The SO 2 absorption cross sections of Bogumil et al (2003) show a clear temperature dependence which has an impact on the retrieved SO 2 SCDs depending on the fitting window used. However, only one temperature (203 K) is used for the DOAS fit, therefore a temperature correction needs to be applied: SCD' = C temp .SCD.…”
Section: Temperature Correctionmentioning
confidence: 99%
“…The AMF depends on the viewing angles and illumination, surface and cloud conditions as well as on the O 3 total column, which is taken from the O 3 total column retrieval. A cloudy and clear-sky AMF is calculated using temperature-dependent cross sections for SO 2 (Bogumil et al, 2003) and O 3 (Brion et al, 1984):…”
Section: Verification Algorithmmentioning
confidence: 99%
“…The formaldehyde absorption spectrum in the near UV between 300 nm and 350 nm ( Fig. 1) was measured many times at different spectral resolutions (Bass et al, 1980;Cantrell, 1990;Rogers, 1990;Meller and Moortgat, 2000;Bogumil et al, 2003;Pope et al, 2005;Smith et al, 2006;Gratien et al, 2007). A recent analysis of the differences in the HCHO spectra by Hak et al (2005) (Meller and Moortgat, 2000;Cantrell, 1990) convolved to a resolution of 0.2 nm and interpolated to a wavelength grid of 0.04 nm.…”
Section: Introductionmentioning
confidence: 99%
“…The spectral resolution of the original HCHO absorption cross sections published range from 3.5 pm (Smith et al, 2006) to 0.11 nm (Bogumil et al, 2003). An effective cross section for broad-band-DOAS can be calculated using any of these cross sections by convolution with an appropriate instrument function.…”
Section: Introductionmentioning