1996
DOI: 10.1016/0021-9290(95)00084-4
|View full text |Cite
|
Sign up to set email alerts
|

Mechanical validation of whole bone composite femur models

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

20
350
0
13

Year Published

2000
2000
2019
2019

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 478 publications
(389 citation statements)
references
References 24 publications
20
350
0
13
Order By: Relevance
“…The use of polyurethane human bone substitutes, as standard materials for implant placement in the mechanical testing of orthopedic implants (ASTM 1839-08) 21 , was suggested by Cristofolini & Viceconti 15,22 , who concluded that synthetic polyurethane bones have a similar flexion to that of bones of cadavers and can therefore constitute a reproducible protocol for the assessment of implant stability. Nacional ® polyurethane blocks were supplied by the manufacturer at three different levels of density: 40, 20 and 15 PCF or 0.64 g/cm 3 , 0.32 g/cm 3 and 0.24 g/cm 3 , respectively, with the following dimensions: height of 4.2 cm, width of 17.8 cm and length of 6.5 cm.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The use of polyurethane human bone substitutes, as standard materials for implant placement in the mechanical testing of orthopedic implants (ASTM 1839-08) 21 , was suggested by Cristofolini & Viceconti 15,22 , who concluded that synthetic polyurethane bones have a similar flexion to that of bones of cadavers and can therefore constitute a reproducible protocol for the assessment of implant stability. Nacional ® polyurethane blocks were supplied by the manufacturer at three different levels of density: 40, 20 and 15 PCF or 0.64 g/cm 3 , 0.32 g/cm 3 and 0.24 g/cm 3 , respectively, with the following dimensions: height of 4.2 cm, width of 17.8 cm and length of 6.5 cm.…”
Section: Resultsmentioning
confidence: 99%
“…Frequencia. for the placement of implants 15 . However, there is still a need, within the scientific community, to find a substrate that is similar to bone tissue and to examine the influence on this substrate of implant surface treatment, immediately after insertion.…”
Section: Conclusãomentioning
confidence: 99%
See 1 more Smart Citation
“…Synthetic femurs were chosen due to the low availability of cadaveric pediatric femurs. The composite femurs have been shown to be similar to cadaver bone during biomechanical tests with low inter-specimen variability [2,3].…”
Section: Methodsmentioning
confidence: 99%
“…Cristofolini et al e Szivek et al, após análises biomecânicas, consideraram os espécimes ósseos de fê-mur em poliuretano adequados para ensaios mecâni-cos, especialmente em análises comparativas, provendo elevada reprodutibilidade (14)(15) . Esses trabalhos ratificaram a nossa escolha pelos espécimes homogêneos.…”