1994
DOI: 10.1177/026765919400900304
|View full text |Cite
|
Sign up to set email alerts
|

Membrane oxygenators: influence of design on performance

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
19
0

Year Published

1996
1996
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 31 publications
(20 citation statements)
references
References 9 publications
1
19
0
Order By: Relevance
“…The advantages of the membrane oxygenator over the bubble oxygenator have led to their widespread use [1][2][3][4][5] despite their more elevated cost. 6 Modifications in their design have aimed towards reductions in the priming volume and surface area in order to minimize haemodilution and blood contact with foreign surfaces.…”
Section: Introductionmentioning
confidence: 99%
“…The advantages of the membrane oxygenator over the bubble oxygenator have led to their widespread use [1][2][3][4][5] despite their more elevated cost. 6 Modifications in their design have aimed towards reductions in the priming volume and surface area in order to minimize haemodilution and blood contact with foreign surfaces.…”
Section: Introductionmentioning
confidence: 99%
“…Anesthesia was induced with ketamine (20 mg/kg, IM, Fort Dodge Laboratories, Ford Dodge, IA) and sodium pentobarbital (3-5 mg/ kg IV as needed, Abbott Laboratories, N. Chicago, IL) [15][16][17][18]. After endotracheal intubation, the pigs were connected to the ventilator.…”
Section: Cardiopulmonary Bypass With a Roller Pump A Hollow-fiber Oxmentioning
confidence: 99%
“…After a median sternotomy, an arterial cannula was inserted into the ascending aorta (16-18F) and a venous cannula (40F) was inserted into the right atrium via the atrial appendage and was retained by purse-string sutures. The arterial and venous lines were connected with components of the CPB [15][16][17][18]. Cardiopulmonary bypass was initiated and the left ventricle was vented via the left atrial appendage.…”
Section: Cardiopulmonary Bypass With a Roller Pump A Hollow-fiber Oxmentioning
confidence: 99%
“…Membrane oxygenators, also known as artificial lungs, are used for extracorporeal membrane oxygenation to support short‐term cardiopulmonary function for patients with respiratory failure . The membranes equipped in membrane oxygenators require high gas transfer performance and excellent hemocompatibility .…”
mentioning
confidence: 99%