Method for Screening and Quantitative Determination of Serum Levels of Salicylic Acid, Acetaminophen, Theophylline, Phenobarbital, Bromvalerylurea, Pentobarbital, and Amobarbital Using Liquid Chromatography/Electrospray Mass Spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
25
0
3

Year Published

2006
2006
2017
2017

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 48 publications
(28 citation statements)
references
References 14 publications
0
25
0
3
Order By: Relevance
“…The detection of APAP in an actual hair specimen obtained from an acute poisoning case revealed that APAP is incorporated into human hair. Recently, liquid chromatography (LC)-MS [12] and LC-MS-MS [13] have gained popularity in drug analyses. However, the GC-MS technique has various advantages over the LC-MS (-MS), because GC-MS instruments are generally much cheaper and are now very common in forensic laboratories.…”
Section: Discussionmentioning
confidence: 99%
“…The detection of APAP in an actual hair specimen obtained from an acute poisoning case revealed that APAP is incorporated into human hair. Recently, liquid chromatography (LC)-MS [12] and LC-MS-MS [13] have gained popularity in drug analyses. However, the GC-MS technique has various advantages over the LC-MS (-MS), because GC-MS instruments are generally much cheaper and are now very common in forensic laboratories.…”
Section: Discussionmentioning
confidence: 99%
“…20,29 Moreover, clean extracts were obtained by using this sorbent when preliminary experiments have been performed to test its suitability. Oasis HLB is a polymeric sorbent with a polar group, with a hydrophilic-lipophilic-balance and reversed-phase interactions.…”
Section: Drug Analysis By In-line Spe-ce-uvmentioning
confidence: 99%
“…This selection was based on the existing literature regarding the off-line SPE process involving barbiturates and Oasis HLB. 20,[29][30][31] The elution plug for the different mixtures tested was introduced into the capillary at 50 mbar for 30 s and was then pushed through the SPE sorbent by introducing the BGE solution at 50 mbar for 220 s. The results demonstrated that the differences in the organic solvent and mixtures tested, in terms of peak area, were not significant. Thus, MeOH was chosen as the elution solvent for further experiments.…”
Section: Study Of the Elution Stepmentioning
confidence: 99%
“…In recent years, several LC-MS and LC-MS/MS methods have been reported for the analysis of acetaminophen and its major urinary metabolites, either alone or in combination with other drugs in biological samples (e.g., Refs. [5][6][7][8][9][10][11][12][13]). In contrast, GC-MS methods for acetaminophen are rare.…”
Section: Introductionmentioning