2012
DOI: 10.4012/dmj.2011-201
|View full text |Cite
|
Sign up to set email alerts
|

Microfractures in metal-ceramic and all-ceramic implant-supported fixed dental prostheses caused by superstructure fixation

Abstract: The effect of ceramic veneering on the passivity of fit of cast metal and CAD/CAM-fabricated zirconia ceramic implant-supported three-unit cement-retained restorations was investigated, as well as the effect of misfit stress on the marginal integrity of ceramic veneers. Superstructures were fabricated using cast metal or by CAD/CAM milling of presintered or HIP zirconia ceramic (n=10). Before and after veneering, strain gages were used to measure in vitro the strain developed in all the restorations as a resul… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0
2

Year Published

2013
2013
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 11 publications
(7 citation statements)
references
References 19 publications
0
5
0
2
Order By: Relevance
“…3,6,[10][11][12][13][14] Clinically acceptable misfit levels have been defined for fixed dental prostheses at between 50 and 120 mm. 3,[15][16][17] For computer-based restorations, a marginal gap of under 200 mm has been stated to be clinically acceptable.…”
mentioning
confidence: 99%
“…3,6,[10][11][12][13][14] Clinically acceptable misfit levels have been defined for fixed dental prostheses at between 50 and 120 mm. 3,[15][16][17] For computer-based restorations, a marginal gap of under 200 mm has been stated to be clinically acceptable.…”
mentioning
confidence: 99%
“…The porcelain veneering process itself might have resulted in microcrack formation at the cervical margins of the bridge retainers as mentioned earlier in the literature by many authors who also stated that cementation of implant supported restorations led to a general increase in the number of detectable microcracks. (33) The marginal gap values of samples fabricated by new CAD/CAM technology were clinically acceptable (34) , furthermore, their fracture resistance results were higher than the normal masticatory forces applied on the premolar and molar teeth. (35)(36)(37) Consequently, the new Co -Cr fabrication technique (CAD/CAM soft milling /post sintering) is considered successful in terms of marginal accuracy and fracture resistance.…”
Section: Discussionmentioning
confidence: 92%
“…Group 3 gathered terms for the one-retainer design of RBFPD as presented in Table 7 [ [43] , [45] , [46] , [47] , [48] , [49] , [50] , [51] , [52] , [53] , [54] , [55] , [56] , [57] , [58] , [59] , [60] , [61] , [62] , [63] , [64] , [65] , [66] , [67] , [68] , [69] , [70] , [71] , [72] , [73] , [74] , [75] , [76] , [77] , [78] , [79] , [80] , [81] , [82] , [83] , [84] , [85] , [86] , [87] , [88] , [89] , [90] , [91] , [92] , [93] , [94] , [95] , [96] , [97] , [98] , [99] , [100] , [101] , [102] , [103] , [104] , [105] , [106] , [107] , [108] ,…”