2020
DOI: 10.1016/j.epsr.2020.106549
|View full text |Cite
|
Sign up to set email alerts
|

Modeling frequency response dynamics in power system scheduling

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 31 publications
(9 citation statements)
references
References 17 publications
0
9
0
Order By: Relevance
“…Since the two-step fitting method has shown its superiority in accuracy compared with its previous methods in [14], the proposed method is only compared with the two-step fitting method in this letter. Some settings about these two methods are shown as follows.…”
Section: B Simulation Results and Analysismentioning
confidence: 99%
“…Since the two-step fitting method has shown its superiority in accuracy compared with its previous methods in [14], the proposed method is only compared with the two-step fitting method in this letter. Some settings about these two methods are shown as follows.…”
Section: B Simulation Results and Analysismentioning
confidence: 99%
“…Photovoltaic generation is at the same time a problem and a potential solution for power grid frequency reserves. In fact, increased photovoltaic penetration without VPPs is a part of the problem, as it decreases the grid inertia Su et al (2020), Zhang et al (2020) and increases the demand for frequency reserves (Karbouj et al, 2019). This increased demand is specifically due to the short-term variability of photovoltaic generation (Sinsel et al, 2020).…”
Section: Nowcasting For Vpp With Photovoltaic Generationmentioning
confidence: 99%
“…Finally, frequency reserve is also becoming inadequate as the uncontrollable generation of renewable energy sources replaces more dispatchable thermal plants. 2 Hence, to mitigate these issues, automatic load frequency control (ALFC) is required. ALFC is employed to restore the system frequency by diminishing the load-generation imbalance.…”
Section: Introduction 1| Introduction and Literature Reviewmentioning
confidence: 99%
“…The combined ALFC-AVR scheme is used to regulate the frequency and voltage simultaneously in the small-signal analysis. 15,16 The authors in References [1][2][3][4][5][6][7][8][9][10][11][12][13][14] have not been considered AVR impacts on their considered systems. Hence, it needs further investigation.…”
Section: Introduction 1| Introduction and Literature Reviewmentioning
confidence: 99%
See 1 more Smart Citation