2018
DOI: 10.1109/tpwrs.2018.2827402
|View full text |Cite
|
Sign up to set email alerts
|

Modeling of DFIG-Based Wind Turbine for Power System Transient Response Analysis in Rotor Speed Control Timescale

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
54
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 124 publications
(56 citation statements)
references
References 22 publications
2
54
0
Order By: Relevance
“…A feed forward technique is also employed, which in Fig.2, is noted as e ∧ dq . This is a common practice to improve disturbance rejection of the current loop from the grid voltage [2], [6], [8], [10], [14], [25]. Although the effectiveness of this method can be deteriorated by the one-sampling delay G + d (z), the amplitude of the disturbance from the grid voltage is dramatically reduced with the help of e ∧ dq , which is certainly valid for sags and swells found in a practical power network.…”
Section: System Modeling and Current Controllers For Gccs In The Srfmentioning
confidence: 99%
See 3 more Smart Citations
“…A feed forward technique is also employed, which in Fig.2, is noted as e ∧ dq . This is a common practice to improve disturbance rejection of the current loop from the grid voltage [2], [6], [8], [10], [14], [25]. Although the effectiveness of this method can be deteriorated by the one-sampling delay G + d (z), the amplitude of the disturbance from the grid voltage is dramatically reduced with the help of e ∧ dq , which is certainly valid for sags and swells found in a practical power network.…”
Section: System Modeling and Current Controllers For Gccs In The Srfmentioning
confidence: 99%
“…Similarly, the root locus of current loop, which is plotted by varying the controller gain k in (8), can be obtained, as shown in Fig.5(a). The two trajectories initiated from p 1,2 ol , are noted as 1 and 2 , respectively. It can be observed that with the increasing of k, trajectories 1 and 2 meet at the point of ''A'' and then depart in the opposite direction, before which the system is over damped.…”
Section: Tuning Of Dcpi Based On Critical Damping In the Discretmentioning
confidence: 99%
See 2 more Smart Citations
“…A DFIG-based wind turbine model was designed in [61], using the time scale of the rotor speed control, to examine the transient response of the generator. The effect of the unique behaviour on the transient stability of the DFIG-controlled SMIB system was evaluated.…”
Section: Transient Stability Analysis In Wecsmentioning
confidence: 99%