2017
DOI: 10.1109/tpel.2016.2645944
|View full text |Cite
|
Sign up to set email alerts
|

Modulation Techniques for Enhanced Reduction in Common-Mode Voltage and Output Voltage Distortion in Indirect Matrix Converters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
22
0
3

Year Published

2019
2019
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 32 publications
(25 citation statements)
references
References 42 publications
0
22
0
3
Order By: Relevance
“…After analyzing 27 possible switching state combinations related to three-to-three-phase MC, it can be noted that 6 of them correspond to rotating voltage space vectors. If the MC is supplied by balanced input voltage (11), the rotating voltage space vectors have the same modules, equal to the amplitude of the input voltage and have the same angular speed on the complex plane. Three of these vectors rotate in counter clockwise direction and are named CCW vectors, and rest of them rotate in clockwise direction and are named as CW vectors (Table 1).…”
Section: Modulation Methods Applied To Three-to-three-phase MCmentioning
confidence: 99%
See 3 more Smart Citations
“…After analyzing 27 possible switching state combinations related to three-to-three-phase MC, it can be noted that 6 of them correspond to rotating voltage space vectors. If the MC is supplied by balanced input voltage (11), the rotating voltage space vectors have the same modules, equal to the amplitude of the input voltage and have the same angular speed on the complex plane. Three of these vectors rotate in counter clockwise direction and are named CCW vectors, and rest of them rotate in clockwise direction and are named as CW vectors (Table 1).…”
Section: Modulation Methods Applied To Three-to-three-phase MCmentioning
confidence: 99%
“…The mentioned conclusions were drawn for the case when the voltages supplying the MC are the sinusoidal balanced voltage (11), and the CMV for three-to-n-phase MC is specified as (12). The U i and ω i in the relation (11) are the amplitude and angular frequency, respectively.…”
Section: Proposed Modulation Strategymentioning
confidence: 99%
See 2 more Smart Citations
“…Generally, MCs can be divided into two main classifications: (a) DMC topologies and (b) and indirect MC (IMC) topologies . Figure A shows the DMC topology consisting of nine bidirectional switches while Figure B shows the general structure of IMC topology.…”
Section: Introductionmentioning
confidence: 99%