Abstract: PurposeThe effective source to surface distance (SSDeff) for different combinations of energy/applicator size of the electron beam produced by the light intraoperative accelerator, a mobile dedicated intraoperative radiotherapy accelerator, has been calculated in this study.MethodsBoth ionometric dosimetry and Monte Carlo (MC) simulation were followed to obtain the SSDeff for different combinations of electron energy/applicator size. Simulations were performed using Monte Carlo Nuclear Particles (MCNP) MC code… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2018
2018
2025
2025

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 14 publications
(3 citation statements)
references
References 20 publications
0
3
0
Order By: Relevance
“…The output beam has a 3 mm diameter and is collimated by the sterilisable cylindrical PMMA applicator through the hard-docking system. Employed applicators are cylindrical tubes with 5 mm thickness and 60 cm length 41 . The diameter of these applicators changes between 3 and 10 cm (3, 4, 5, 6, 7, 8 and 10 cm), and their base angle changes from 0° to 45° (0°, 15°, 30° and 45°) 42 .…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The output beam has a 3 mm diameter and is collimated by the sterilisable cylindrical PMMA applicator through the hard-docking system. Employed applicators are cylindrical tubes with 5 mm thickness and 60 cm length 41 . The diameter of these applicators changes between 3 and 10 cm (3, 4, 5, 6, 7, 8 and 10 cm), and their base angle changes from 0° to 45° (0°, 15°, 30° and 45°) 42 .…”
Section: Resultsmentioning
confidence: 99%
“…Employed applicators are cylindrical tubes with 5 mm thickness and 60 cm length. 41 The diameter of these applicators changes between 3 and 10 cm (3, 4, 5, 6, 7, 8 and 10 cm), and their base angle changes from 0°to 45°(0°, 15°, 30°a nd 45°). 42 The length of employed applicators is equal to 60 cm.…”
Section: Liacmentioning
confidence: 99%
“…The gamma index calculations were performed by Gnuplot software (version 4.4 patch level 3; Geek net Inc., Fairfax, VA, USA) using its gamma index executive file. 17…”
Section: Simulationmentioning
confidence: 99%