2006
DOI: 10.1016/j.sab.2006.02.009
|View full text |Cite
|
Sign up to set email alerts
|

Multipumping flow system for improving hydride generation atomic fluorescence spectrometric determinations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2007
2007
2014
2014

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 16 publications
0
3
0
Order By: Relevance
“…The working linear range varied between 0.15 and 6.0 mg L À1 with a good correlation coefficient (r) of 0.9994. The analytical performance of the proposed SIA-LAV-HG-AAS method has been improved in terms of sensitivity compared to SIA and multisyringe ow injection (MS-FI) systems 7,12,17 and is relatively comparable to other systems using atomic uorescence spectrometry [14][15][16] or ICP-MS (ref. 8) as the detector.…”
Section: Analytical Performance and Applicationsmentioning
confidence: 99%
See 1 more Smart Citation
“…The working linear range varied between 0.15 and 6.0 mg L À1 with a good correlation coefficient (r) of 0.9994. The analytical performance of the proposed SIA-LAV-HG-AAS method has been improved in terms of sensitivity compared to SIA and multisyringe ow injection (MS-FI) systems 7,12,17 and is relatively comparable to other systems using atomic uorescence spectrometry [14][15][16] or ICP-MS (ref. 8) as the detector.…”
Section: Analytical Performance and Applicationsmentioning
confidence: 99%
“…7 Automatic on-line ow techniques have proved to be rapid, simple, highly sensitive, precise and accurate for such a type of analysis eliminating many disadvantages of batch-HG systems, like high sample and reagent consumption, laborious processes, great risk of contamination and analyte loss. In the literature, many automated on-line hydride generation systems such as continuous ow (CF), 8,9 ow injection (FI), 7,10,11 sequential injection (SI), 12,13 lab-on-valve (LOV), 14,15 multi-pumping (MPFS) 16 and multisyringe ow systems (MSFIA) 17,18 have been developed in order to eliminate the above-mentioned drawbacks.…”
Section: Introductionmentioning
confidence: 99%
“…They validated the procedure by the accurate analysis of NRCC DOLT-2 (Dogfish Liver) and NIST SRM 1648 (Urban Particulate Matter). Lopez-Garcia et al 125 replaced the peristaltic pumping of the conventional HG flow manifold with membrane micropumps. They decreased sample and reagent consumption 8-9 fold with no deterioration in sensitivity for an AFS system.…”
Section: Chemical Vapour Generationmentioning
confidence: 99%