Nanoindentation Measurement of Mechanical Properties of Soft Solid Covered By a Thin Liquid Film

Abstract: AThe presence of a surface-covering liquid film may significantly affect property measurement by nanoindentation on an underlying solid specimen, by causing an artificial drift of the reference point for tip displacement and exerting a surface-tension traction on the tip. The first effect can be corrected for by identifying the hard contact point between the tip and the solid in the load-displacement curve. The second effect can be corrected for by a formula derived in this work, which can also correct for the… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2009
2009
2020
2020

Publication Types

Select...
8
2

Relationship

1
9

Authors

Journals

citations
Cited by 20 publications
(9 citation statements)
references
References 19 publications
0
9
0
Order By: Relevance
“…(2) will be the instantaneous value at the moment when the rate jump is applied [36]. The validity of this rate-jump 11 method in general has been verified in a wide range of soft materials on different mechanical testing platforms, including depth-sensing indentation on bone tissues, polymers and soft metals [18,37,38], micro-plate compression on stem-cell inserted collagen micro-masses for tissue engineering purposes [39], AFM nanoindentation of cells and soft polymers [19,20,39], as well as macroscopic uniaxial tensile testing on polymers [40]. In the results below, the values of the Young modulus E are reported and these were calculated from the measured reduced moduli…”
Section: Atomic Force Microscopy Nanoindentationmentioning
confidence: 96%
“…(2) will be the instantaneous value at the moment when the rate jump is applied [36]. The validity of this rate-jump 11 method in general has been verified in a wide range of soft materials on different mechanical testing platforms, including depth-sensing indentation on bone tissues, polymers and soft metals [18,37,38], micro-plate compression on stem-cell inserted collagen micro-masses for tissue engineering purposes [39], AFM nanoindentation of cells and soft polymers [19,20,39], as well as macroscopic uniaxial tensile testing on polymers [40]. In the results below, the values of the Young modulus E are reported and these were calculated from the measured reduced moduli…”
Section: Atomic Force Microscopy Nanoindentationmentioning
confidence: 96%
“…5,6,20 Surface adhesion between the specimen and the probe, and other effects pertinent to wet or moist samples, such as hydrodynamic forces resulting from infiltrated liquid in porous samples or for samples immersed in liquid, are ignored. These are challenging test conditions to model from a mechanics viewpoint, and more work needs to be done in this area, 21 although simple analytical models are not expected to exist generally.…”
Section: Discussionmentioning
confidence: 98%
“…At least 30 min were given to stabilize the system and rehydrate the samples before the loading was applied on the micro-cantilevers. Effects on the measurement due to the viscoelasticity of the sample and meniscus forces from the fluid were corrected using a protocol described by Ngan et al (2005) and Tang and Ngan (2007).…”
Section: Nanoindentationmentioning