2016
DOI: 10.4028/www.scientific.net/msf.858.1099
|View full text |Cite
|
Sign up to set email alerts
|

Newly Developed Switching Analysis Method for 3.3 kV 400 a Full SiC Module

Abstract: We have demonstrated a new analysis method using a precise equivalent circuit of 3.3 kV 400 A full SiC modules and showed that the calculated waveforms well agree with the measured waveforms. We have also examined the current distribution in the module by utilizing this equivalent circuit model.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2017
2017
2019
2019

Publication Types

Select...
2
2

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 5 publications
0
2
0
Order By: Relevance
“…To reduce the complexity of the equivalent lumped circuit representing the HF behavior of the package and the PCB layout, the dominant parasitic parameters have to be determined [14]. In the first approximation, the mutual resistances, the mutual inductive couplings with a coupling coefficient below 0.1, and the mutual capacitances below 1 pH calculated by Q3D are neglected.…”
Section: Virtual Dynamic Characterizationmentioning
confidence: 99%
“…To reduce the complexity of the equivalent lumped circuit representing the HF behavior of the package and the PCB layout, the dominant parasitic parameters have to be determined [14]. In the first approximation, the mutual resistances, the mutual inductive couplings with a coupling coefficient below 0.1, and the mutual capacitances below 1 pH calculated by Q3D are neglected.…”
Section: Virtual Dynamic Characterizationmentioning
confidence: 99%
“…The Q3D extractor was used to estimate the frequency-dependent self-and mutualinductances, self-resistances, and self-and mutual-capacitances as previously described, of the power PCB, Device under Test (DUT) PCB, and TO-247 package structure, see Figure 3. To reduce the complexity of the equivalent lumped circuit representing the HF behavior of the package and the PCB layout, the dominant parasitic parameters have to be determined (22). Therefore, the mutual resistances, the mutual inductive couplings with a coupling coefficient below 0.1, and the mutual capacitances below 1pH calculated automatically by Q3D are neglected.…”
Section: Virtual Dynamic Characterizationmentioning
confidence: 99%