2019
DOI: 10.1016/j.compbiomed.2019.01.014
|View full text |Cite
|
Sign up to set email alerts
|

Novel cone-and-plate flow chamber with controlled distribution of wall fluid shear stress

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 10 publications
(4 citation statements)
references
References 17 publications
0
4
0
Order By: Relevance
“…A custom-made cone-plate device consisting of a stationary plate underneath a rotating cone (Figure 1A,B) was used to generate FSS to the cells. The cone was fabricated in accordance with hydrodynamics calculation, 40,41 in which a uniform wall FSS field was provided on the cell surface (Figure 1C,D). MSCs were treated with 0, 0.5, or 0.8 Pa FSS for 1 h each time, three times a day, in accordance with the fluid mechanics calculations and experiments (Figure S1).…”
Section: Application Of Fluid Shear Stressmentioning
confidence: 99%
“…A custom-made cone-plate device consisting of a stationary plate underneath a rotating cone (Figure 1A,B) was used to generate FSS to the cells. The cone was fabricated in accordance with hydrodynamics calculation, 40,41 in which a uniform wall FSS field was provided on the cell surface (Figure 1C,D). MSCs were treated with 0, 0.5, or 0.8 Pa FSS for 1 h each time, three times a day, in accordance with the fluid mechanics calculations and experiments (Figure S1).…”
Section: Application Of Fluid Shear Stressmentioning
confidence: 99%
“…The CPD also allows for long-term exposure to FSS; therefore, this model is well-suited for studying both the acute and chronic endothelial response (seconds–weeks) [ 52 ]. The system is limited by its low throughput in exposing ECs in a single dish to FSS; however, variations using multiple cones connected to a single motor allow for increased output [ 54 ]. Using this model, it is possible to generate FSS of varying magnitudes and directionality.…”
Section: Cone and Platementioning
confidence: 99%
“…As in vivo fluid in bone cavities is difficult to directly observe, some in vitro loading devices were constructed to exert fluid flow on cells. Compared with cone-and-plate flow chamber [ 6 8 ], parallel-plate flow chamber is widely used to produce wall FSS in vitro on cells due to its advantage of controlling the FSS field [ 9 11 ].…”
Section: Introductionmentioning
confidence: 99%