2020
DOI: 10.4236/ojrad.2020.102011
|View full text |Cite
|
Sign up to set email alerts
|

Occupational Eye Lens Radiation Dose While Performing Interventional Procedures over 18 Months Using a Face-Shield Equipped Suspended Radiation Protection System

Abstract: Background: Numerous studies have demonstrated increasing evidence for cataractogenesis at lower levels of ionizing radiation than previously believed, with some suggesting possible absence of a threshold. Genetic differences between individuals also result in increased susceptibility in some operators, who might not be aware. European occupational exposure limits have been reduced and operators are seeking protective measures. Objective: To evaluate the protective effect of a face-shield equipped suspended pr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(1 citation statement)
references
References 46 publications
0
1
0
Order By: Relevance
“…In the case of our study, for example, the differences between eye lens doses normalised to DAP for CA/PCI and RFA/CRYA (0.629 µSv/Gycm 2 vs. 0.496 µSv/Gycm 2 ) might be due to few dynamic factors such as the shielding (only ZG vs. ZG and CSS), the access (radial vs. femoral) and projections used [large variety of different types vs. restricted to few (mainly PA)]. Their relatively high values with respect to other studies, 0.017 µSv/Gycm 2 in Savage et al ( 2013 ), 0.006 µSv/Gycm 2 in both Kwarcinski et al 2020 and Ray et al 2013 and 0.123 µSv/Gycm 2 in Haussen et al 2016 , might be also due to relatively low sensitivity of TLDs and estimated LDL used to assess the exposure for RFA/CRYA (all measured eye lens doses were below LDL). Therefore, the value of 0.496 µSv/Gycm 2 is, in fact, the upper limit of left eye lens doses normalised to DAP for ablations.…”
Section: Discussionmentioning
confidence: 84%
“…In the case of our study, for example, the differences between eye lens doses normalised to DAP for CA/PCI and RFA/CRYA (0.629 µSv/Gycm 2 vs. 0.496 µSv/Gycm 2 ) might be due to few dynamic factors such as the shielding (only ZG vs. ZG and CSS), the access (radial vs. femoral) and projections used [large variety of different types vs. restricted to few (mainly PA)]. Their relatively high values with respect to other studies, 0.017 µSv/Gycm 2 in Savage et al ( 2013 ), 0.006 µSv/Gycm 2 in both Kwarcinski et al 2020 and Ray et al 2013 and 0.123 µSv/Gycm 2 in Haussen et al 2016 , might be also due to relatively low sensitivity of TLDs and estimated LDL used to assess the exposure for RFA/CRYA (all measured eye lens doses were below LDL). Therefore, the value of 0.496 µSv/Gycm 2 is, in fact, the upper limit of left eye lens doses normalised to DAP for ablations.…”
Section: Discussionmentioning
confidence: 84%