1988
DOI: 10.1039/an9881300125
|View full text |Cite
|
Sign up to set email alerts
|

On-line pre-concentration and determination of lead in potable water by flow injection atomic absorption spectrometry

Abstract: A flow injection system incorporating a micro-column of activated alumina was used in conjunction with flame atomic absorption spectrometry for the pre-concentration and determination of lead in drinking waters. The analyte was deposited on the alumina micro-column {basic form of alumina) during the sampting stage and elution was effected by injection of nitric acid (250 yl, 2 M). The procedure was successfully applied to a range of water samples and the accuracy was assessed through recovery experiments, the … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
18
0
1

Year Published

1989
1989
2007
2007

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 64 publications
(19 citation statements)
references
References 0 publications
0
18
0
1
Order By: Relevance
“…This manifold design, in common with others reported recently [83][84][85], allows the unretained sample components to flow through the nebulizer with the consequent risk of blockage in the case of samples with a high dissolved solid content. Two papers [84,85] described the use of activated basic alumina for the retention of lead (from a tap-water matrix) and cadmium (from a urine matrix).…”
Section: Liquid-solid Extractionmentioning
confidence: 92%
See 1 more Smart Citation
“…This manifold design, in common with others reported recently [83][84][85], allows the unretained sample components to flow through the nebulizer with the consequent risk of blockage in the case of samples with a high dissolved solid content. Two papers [84,85] described the use of activated basic alumina for the retention of lead (from a tap-water matrix) and cadmium (from a urine matrix).…”
Section: Liquid-solid Extractionmentioning
confidence: 92%
“…Two papers [84,85] described the use of activated basic alumina for the retention of lead (from a tap-water matrix) and cadmium (from a urine matrix).…”
Section: Liquid-solid Extractionmentioning
confidence: 99%
“…A determinação quantitativa de metais-traço em amostras reais normalmente não é satisfatoriamente conduzida sem as etapas iniciais de separação e/ou pré-concentração, mesmo quando são aplicados métodos sensíveis, como a espectrometria de absorção atômica com geração de hidretos ou atomização eletrotérmica e a espectrometria de emissão atômica utilizando plasma 14 . A complexidade das matrizes analisadas leva à necessidade da inserção dessas etapas no processo analítico, que aumentam a concentração da espé-cie de interesse e eliminam interferências contidas na amostra, tornando-a mais facilmente analisável 15 .…”
Section: Revisão Bibliográficaunclassified
“…[6][7][8][9] Besides, ion-exchange concentration/separation has proven to be an effective means for enhancing the sensitivity and improving the selectivity in analytical determinations.…”
mentioning
confidence: 99%
“…5 Some of them have exploited C18 or ion-exchange resins followed by atomic absorption spectrometry. [6][7][8][9] Besides, ion-exchange concentration/separation has proven to be an effective means for enhancing the sensitivity and improving the selectivity in analytical determinations. 10 There has been increasingly interest concerning in-line concentration since 1980 10,11 , and several modifications have been proposed to improve its performance.…”
mentioning
confidence: 99%