2014 14th International Conference on Environment and Electrical Engineering 2014
DOI: 10.1109/eeeic.2014.6835879
|View full text |Cite
|
Sign up to set email alerts
|

On the control of main substations between transmission and distribution systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
11
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
3
3
1

Relationship

2
5

Authors

Journals

citations
Cited by 15 publications
(11 citation statements)
references
References 6 publications
0
11
0
Order By: Relevance
“…In a further study [10], the same authors discussed a flexible battery management system whereby higher profits could be achieved than with a fixed-operation strategy for the use of battery units. This topic was also explored in [11], with the goal of ensuring both practical and optimal operational strategies, which was accomplished based on consideration of a flexible A-R-OPF with a flexible on-load-tap-changer (OLTC) control system.…”
Section: Recent Developments Of Ds Planning With Esmentioning
confidence: 99%
“…In a further study [10], the same authors discussed a flexible battery management system whereby higher profits could be achieved than with a fixed-operation strategy for the use of battery units. This topic was also explored in [11], with the goal of ensuring both practical and optimal operational strategies, which was accomplished based on consideration of a flexible A-R-OPF with a flexible on-load-tap-changer (OLTC) control system.…”
Section: Recent Developments Of Ds Planning With Esmentioning
confidence: 99%
“…This can be achieved if a suitable number of taps is used [23]. The TR capacity is constrained in this paper as follows [2]: S1 S1.max…”
Section: B Substation Transformermentioning
confidence: 99%
“…In summary, the issue of metering bidirectional power [18] due to possible reverse active and reactive power flows [19][20][21][22] in a transformer (TR) [23] which is typically used to connect different voltage levels in power systems, as seen in Fig. 1, is of high interest and major importance for the society of power and energy systems.…”
mentioning
confidence: 99%
“…This can be achieved if a suitable number of taps is available [31]. The TR capacity is constrained in this paper by:…”
Section: Substation Transformermentioning
confidence: 99%
“…In summary, the issue of metering bidirectional power [26] due to possible reverse active and reactive power flows [27][28][29][30] in a transformer (TR) [31] which is typically used to connect different voltage levels in power systems, as seen in Figure 1, is of high interest and major importance for the society of power and energy systems. This represents a combined technical and economical complex problem, and, therefore, more studies are required in this area.…”
Section: Figurementioning