2013
DOI: 10.3133/tm1d5
|View full text |Cite
|
Sign up to set email alerts
|

Optical techniques for the determination of nitrate in environmental waters: Guidelines for instrument selection, operation, deployment, maintenance, quality assurance, and data reporting

Abstract: The recent commercial availability of in situ optical sensors, together with new techniques for data collection and analysis, provides the opportunity to monitor a wide range of water-quality constituents on time scales in which environmental conditions actually change. Of particular interest is the application of ultraviolet (UV) photometers for in situ determination of nitrate concentrations in rivers and streams. The variety of UV nitrate sensors currently available differ in several important ways related … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
86
0
1

Year Published

2015
2015
2018
2018

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 76 publications
(88 citation statements)
references
References 7 publications
(9 reference statements)
1
86
0
1
Order By: Relevance
“…This sensor, designed and constructed by scientists at the Monterey Bay Aquarium Research Institute, allowed real-time NO 3 -N monitoring of the tile drainage. ISUS sensors and the related SUNA (submersible UV nitrate analyzer) sensor have been shown to provide accurate NO 3 -N determination in a variety of ground and surface waters (Pellerin et al 2013;Sackmann 2011).…”
Section: Tim Hartz Tim Hartzmentioning
confidence: 99%
“…This sensor, designed and constructed by scientists at the Monterey Bay Aquarium Research Institute, allowed real-time NO 3 -N monitoring of the tile drainage. ISUS sensors and the related SUNA (submersible UV nitrate analyzer) sensor have been shown to provide accurate NO 3 -N determination in a variety of ground and surface waters (Pellerin et al 2013;Sackmann 2011).…”
Section: Tim Hartz Tim Hartzmentioning
confidence: 99%
“…A regression of depth and width-integrated discrete nitrate plus nitrite concentrations with sensor nitrate concentrations on 11-22 dates shows that the two were strongly correlated (r 2 5 0.97-0.99) across a range of flow conditions at all three sites (Figure 2). Sensor bias relative to laboratory measurements were corrected as described in Pellerin et al [2013]. This is the primary step in our postprocessing, as burst data and metadata (such as the fitting parameter) are used in real-time to assure high data quality.…”
Section: 1002/2015wr017753mentioning
confidence: 99%
“…All instruments were equipped with an external nylon brush wiper (Zebra-Tech, New Zealand) that cleaned the optical windows prior to every sampling interval. Nitrate sensor performance was checked prior to and during field deployments as explained in Pellerin et al [2013]. Briefly, this includes blank and standard checks, as well as comparison to discrete samples collected at or near the site.…”
Section: 1002/2015wr017753mentioning
confidence: 99%
“…Exceptions were nitrate and chlorophyll; the turbid water column, high DOC (Pellerin et al, 2013), or initial instrument calibration, probably affected the quality of our SUNA NO 3 measurements. Fortunately, the observed interference appeared to be consistent and therefore the LOBO measurements were corrected using direct comparisons with discrete samples.…”
Section: Discussionmentioning
confidence: 89%