1999
DOI: 10.1016/s0378-4347(98)00511-8
|View full text |Cite
|
Sign up to set email alerts
|

Optimization of separation of a complex mixture of natural and synthetic corticoids by micellar liquid chromatography using sodium dodecyl sulphate

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0

Year Published

2003
2003
2015
2015

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 22 publications
(13 citation statements)
references
References 22 publications
0
13
0
Order By: Relevance
“…The extraction procedure was adapted from the literature [11]: to a 3.00 mL portion of thawed membrane-filtered sample, 0.35 g NaCl, 0.5 g Na 2 HPO 4 (to raise the pH to 9.0), and 4.00 mL dichloromethane were added; the organic layer was removed, dried with anhydrous Na 2 SO 4 , evaporated to dryness, reconstituted into 50 mL methanol, and diluted with 450 mL 5 mmol/L SDS/5 mmol/L tetraborate solution prior to injection.…”
Section: Sample Preparationmentioning
confidence: 99%
See 1 more Smart Citation
“…The extraction procedure was adapted from the literature [11]: to a 3.00 mL portion of thawed membrane-filtered sample, 0.35 g NaCl, 0.5 g Na 2 HPO 4 (to raise the pH to 9.0), and 4.00 mL dichloromethane were added; the organic layer was removed, dried with anhydrous Na 2 SO 4 , evaporated to dryness, reconstituted into 50 mL methanol, and diluted with 450 mL 5 mmol/L SDS/5 mmol/L tetraborate solution prior to injection.…”
Section: Sample Preparationmentioning
confidence: 99%
“…For confirmatory testing, chromatographic techniques such as GC and LC, especially when coupled to MS, are usually preferred [2,[7][8][9]. The unique selectivity of micellar LC (MLC) systems has been demonstrated for anabolic steroids and corticosteroids determination [10,11] and as a means to mimicking membrane structure [12]. In gen- eral, these approaches require qualified operators, complex instrumentation, whose maintenance is relatively costly, and often samples must be derivatized prior to injection.…”
Section: Introductionmentioning
confidence: 99%
“…In previous papers, the optimization of the separation of a complex mixture of natural and synthetic corticoids [17] and urinary steroids (corticoids and anabolics) [18] in MLC using SDS and different organic modifiers has been reported. To improve column efficiency, higher temperatures and smaller flow-rates than those used in HPLC were proposed.…”
Section: Preliminary Considerationsmentioning
confidence: 99%
“…MLC has been employed for separation studies of complex mixtures of corticoids, urinary steroids (corticoids and anabolics) [17,18] and for the determination of single anabolic compounds in pharmaceuticals [9].…”
Section: Introductionmentioning
confidence: 99%
“…Micellar liquid chromatography (MLC) has proved to be a useful technique in the determination of diverse groups of drugs in urine, such as barbiturates [12], natural and synthetic corticosteroids [13], 13-antagonists [14], steroids [15] and nicotine and cotidine [16].…”
Section: Introductionmentioning
confidence: 99%