ORIGIN: a novel and compact Laser Desorption – Mass Spectrometry system for sensitive in situ detection of amino acids on extraterrestrial surfaces

Abstract: For the last four decades space exploration missions have searched for molecular life on planetary surfaces beyond Earth. Often pyrolysis gas chromatography mass spectrometry has been used as payload on such space exploration missions. These instruments have relatively low detection sensitivity and their measurements are often undermined by the presence of chloride salts and minerals. Currently, ocean worlds in the outer Solar System, such as the icy moons Europa and Enceladus, represent potentially habitable … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
53
0

Year Published

2020
2020
2025
2025

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 31 publications
(56 citation statements)
references
References 45 publications
(56 reference statements)
3
53
0
Order By: Relevance
“…We introduced two LIMS instruments designed in our group: a miniature LIMS instrument, (LMS) for space research, and a large laboratory LIMS system, LMS-GT [21,24,25,132]. Recently, another miniature LIMS system called ORIGIN equipped with ns-laser desorption source was developed for detection of amino acids on planetary surfaces [12]. All these instruments use a characteristic collinear or axial ion extraction method.…”
Section: Selected Femtosecond-lims Systemsmentioning
confidence: 99%
See 3 more Smart Citations
“…We introduced two LIMS instruments designed in our group: a miniature LIMS instrument, (LMS) for space research, and a large laboratory LIMS system, LMS-GT [21,24,25,132]. Recently, another miniature LIMS system called ORIGIN equipped with ns-laser desorption source was developed for detection of amino acids on planetary surfaces [12]. All these instruments use a characteristic collinear or axial ion extraction method.…”
Section: Selected Femtosecond-lims Systemsmentioning
confidence: 99%
“…Current high laser fluence LIMS designs have significantly improved mass resolution. For LMS, an instrument with about a 30 cm flight path, the mass resolution close to 700 in ablation mode [11,21,132] and 1100 in desorption mode [12] was obtained, whereas the measurements with LMS-GT can be conducted with the mass resolution of 15,000 and higher [24]. A new strategy to reduce temporal ion spread produced during laser ablation was applied in high irradiance LI-O-TOFMS instrument with inert gas cooling and orthogonal extraction [23,129].…”
Section: Time Of Flight Mass Range and Mass Resolutionmentioning
confidence: 99%
See 2 more Smart Citations
“…Finally, some work now is focusing on a lander instrument on Europa, particularly on a coupling of the mass analyser with sample introduction/laser ablation/desorption ion source (Origin instrument). This instrument is more like LMS with the laser ablation/desorption ion source (Ligterink, et al, 2020).…”
Section: Heritage Of Miniaturised Instruments For Forthcoming Missionsmentioning
confidence: 99%