2014
DOI: 10.1016/j.jash.2014.08.014
|View full text |Cite
|
Sign up to set email alerts
|

Oscillometric blood pressure: a review for clinicians

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
90
0
6

Year Published

2015
2015
2024
2024

Publication Types

Select...
5
2
2

Relationship

0
9

Authors

Journals

citations
Cited by 181 publications
(103 citation statements)
references
References 8 publications
0
90
0
6
Order By: Relevance
“…Empirical methods are used, similar to cuff-based devices that use fixed-ratio or similar methods to compute brachial BP from an arm oscillogram ( 6 , 7 ). In the fixed-ratio method, mean BP is first obtained as the cuff pressure at which the oscillogram is maximal, and systolic and diastolic BP are then determined as the cuff pressure at which the oscillogram is some fixed ratio of its maximal value.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Empirical methods are used, similar to cuff-based devices that use fixed-ratio or similar methods to compute brachial BP from an arm oscillogram ( 6 , 7 ). In the fixed-ratio method, mean BP is first obtained as the cuff pressure at which the oscillogram is maximal, and systolic and diastolic BP are then determined as the cuff pressure at which the oscillogram is some fixed ratio of its maximal value.…”
Section: Methodsmentioning
confidence: 99%
“…We proposed to extend the oscillometric principle, which is the basis of most automatic cuff-based BP measurement devices ( 6 , 7 ), for cuff-less BP measurement using a smartphone. In this scenario, the user serves as the actuator (instead of the cuff) by pressing her/his finger against the phone to vary the external pressure of the underlying artery, whereas the phone serves as the sensor (rather than the cuff) to measure the resulting variable-amplitude blood volume variations or oscillations and applied pressure.…”
Section: Introductionmentioning
confidence: 99%
“…La medida de la PANI se basa en la oclusión de una arteria por un manguito presurizado y después la medida de las oscilaciones de la presión del manguito o la presión a la cual reaparece el flujo en la arteria mientras se deshincha el manguito 127 . Existen varias técnicas para determinar la PA mediante este método:…”
Section: Monitorización No Invasiva (Pani)unclassified
“…AOBP devices use the oscillometric technique to estimate BP -systolic and diastolic BP are derived indirectly through algorithm-based analysis of oscillometric waveforms [4]. Many of the leading oscillometric devices have undergone extensive testing to validate BP measurements and, on the basis of this testing, the proprietary algorithms specific to each device have been refined to optimize accuracy.…”
Section: Introductionmentioning
confidence: 99%