2017
DOI: 10.1016/j.ajic.2017.06.025
|View full text |Cite
|
Sign up to set email alerts
|

Outbreak of health care-associated Burkholderia cenocepacia bacteremia and infection attributed to contaminated sterile gel used for central line insertion under ultrasound guidance and other procedures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
23
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 28 publications
(23 citation statements)
references
References 18 publications
0
23
0
Order By: Relevance
“…It is critical, when using ultrasound gel for the placement of both central and peripheral cannulas, to ensure both the sterility of the coupling gel and the ultrasound probe and that an aseptic cannula insertion technique is used at all times, especially when dealing with high-risk patients. 18 In terms of effective infection prevention and control measures that managed to cease the rising number of cases associated with each reported outbreak, the most effective approaches used a combination of environmental-, staff-and patient-related measures. For instance, those outbreaks in which a combination of actions, such as equipment maintenance, routine education programs for staff and patient confinement were reported, were shorter.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…It is critical, when using ultrasound gel for the placement of both central and peripheral cannulas, to ensure both the sterility of the coupling gel and the ultrasound probe and that an aseptic cannula insertion technique is used at all times, especially when dealing with high-risk patients. 18 In terms of effective infection prevention and control measures that managed to cease the rising number of cases associated with each reported outbreak, the most effective approaches used a combination of environmental-, staff-and patient-related measures. For instance, those outbreaks in which a combination of actions, such as equipment maintenance, routine education programs for staff and patient confinement were reported, were shorter.…”
Section: Discussionmentioning
confidence: 99%
“…For instance, those outbreaks in which a combination of actions, such as equipment maintenance, routine education programs for staff and patient confinement were reported, were shorter. 18,47,[62][63][64] Findings from the review suggest that the point sources for B. cepacia HAIs were often contaminated fluids, which in some instances were contaminated during manufacture. Substandard manufacturing of products distributed globally undermines the efficiency of implemented control measures and may boost the trend of outbreak-related cases worldwide.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Recently reported outbreaks resulted in patient death and bacteremia associated with contaminated gel used during CVC placements. 8,9 These studies described pathogen transmission during ultrasound procedures, and demonstrate that the probe contacts the puncture site because typically gel is moved around by the probe to visualize the anatomy. Because probe sheaths break (reviewed in the CDC guidelines) and may become contaminated during application to the probe, the probe still needs a minimum of HLD before use in these procedures.…”
Section: Discussionmentioning
confidence: 99%
“…7 Numerous outbreaks implicating contaminated ultrasound gel have also occurred, including cases where bacteremia and death resulted. 8,9 These outbreaks demonstrate the risks associated with surface ultrasound-guided procedures and suggest the probe and gel can contaminate the puncture site during imaging. Appropriate use of sterile gel and adequate ultrasound probe reprocessing play key roles in preventing these adverse events.…”
mentioning
confidence: 99%