2012
DOI: 10.1007/s12206-011-1250-x
|View full text |Cite
|
Sign up to set email alerts
|

Parametric study on flow and heat transfer characteristics of porous wick evaporator based on AMTEC

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 21 publications
0
4
0
Order By: Relevance
“…4 One principle when generating electricity by neutralizing sodium atoms is prevention of backpressure buildup (concentration losses) at the BASE/cathode interface. Currently, sodium atoms do not move easily either into or out of b-alumina at temperatures below 750 K. 5,6 The operating design and desirable operating temperatures of the AMTEC system were 900 K to 1300 K in the evaporator section and 600 K in the condenser section. The AMTEC system operates at efficiency of over 20%.…”
Section: Anmentioning
confidence: 99%
See 2 more Smart Citations
“…4 One principle when generating electricity by neutralizing sodium atoms is prevention of backpressure buildup (concentration losses) at the BASE/cathode interface. Currently, sodium atoms do not move easily either into or out of b-alumina at temperatures below 750 K. 5,6 The operating design and desirable operating temperatures of the AMTEC system were 900 K to 1300 K in the evaporator section and 600 K in the condenser section. The AMTEC system operates at efficiency of over 20%.…”
Section: Anmentioning
confidence: 99%
“…The AMTEC system operates at efficiency of over 20%. 7 Wu et al 5 established an axisymmetric invariable temperature phase change interface model of a porous evaporator wick based on an AMTEC. Previously, Rhi et al 8 presented thermal modeling of an AMTEC system using an analytical one-dimensional (1-D) simulation method for a single cell.…”
Section: Anmentioning
confidence: 99%
See 1 more Smart Citation
“…The authors once did a thorough review of the state of the art in the research and development of the AMTEC [2]. It was revealed that, the researches about AMTEC mainly focus on its overall performance test and optimization [4,5], application fields [6], material and structure design [7,8], numerical simulation of flow and thermal performance, heat loss, as well as the heat and mass transfer characteristics of capillary evaporator [9,10]. Comparatively speaking, little attention has paid to the porous wick condenser.…”
Section: Introductionmentioning