Performance Evaluation of Nine Hormone Assays on the Immulite 2000®Immunoassay System

Abstract: We evaluated the analytical performance of the Immulite 2000 immunoassay analyzer (Diagnostic Products Corporation, Los Angeles, USA) based on a new detection technology, electrochemical luminescence. The evaluated analytes were thyrotropin, triiodothyronine, free thyroxine, follitropin, lutropin, prolactin, cortisol, estradiol and progesterone. We tested the assay precision, linearity, recovery, and correlation with comparison methods for these analytes. For most assays, within-run and between-day imprecision… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2004
2004
2013
2013

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 18 publications
(7 citation statements)
references
References 4 publications
0
7
0
Order By: Relevance
“…This contradiction highlights the need for careful evaluation of each assay used for the diagnosis of CPP. The Immulite 2000 LH assay showed good correlation to the Magia LH assay (10).…”
Section: Discussionmentioning
confidence: 89%
“…This contradiction highlights the need for careful evaluation of each assay used for the diagnosis of CPP. The Immulite 2000 LH assay showed good correlation to the Magia LH assay (10).…”
Section: Discussionmentioning
confidence: 89%
“…No significant differences were observed for the cortisol and cortisone concentrations and for the cortisone/cortisol ratio between the genders. Previously, cortisol concentrations in plasma for adults were reported to be 60 -230 Ag/ l by an IA-based method [16]. Lower reference intervals for urinary free cortisol were reported in adult females by LC-MS/MS based methods compared with IA methods [17,20].…”
Section: Discussionmentioning
confidence: 99%
“…Historically, immunoassay (IA)-based methods were widely used for cortisol analysis [16]. These methods may be susceptible to interference from cortisone and other steroid metabolites.…”
Section: Introductionmentioning
confidence: 99%
“…Progesterone and estradiol levels were measured using the Immulite 2000 immunoassay analyzer (Diagnostic Products Corporation, Los Angeles, CA) that employs electrochemical luminescence for detection. 42 Lower limits of detection for estradiol and progesterone were 10 pg/mL and 0.1 ng/mL, respectively.…”
Section: Estrogen and Progesterone Hormonal Levelsmentioning
confidence: 93%