2009
DOI: 10.1002/jrs.2387
|View full text |Cite
|
Sign up to set email alerts
|

Performing tip‐enhanced Raman spectroscopy in liquids

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
182
0
5

Year Published

2013
2013
2022
2022

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 164 publications
(189 citation statements)
references
References 53 publications
(49 reference statements)
2
182
0
5
Order By: Relevance
“…Thus, electromagnetic enhancement is resulted for the incident excitation field and the emitted Raman signal for R6G molecules in close vicinity to the Ag surface. The AEF value of 2 Â 10 4 achieved in case of the Ag coated microneedle is comparable to that reported [21] in a different experimental setup in which about an enhancement factor of 10 4 was achieved using a Agcoated tip. Our Ag-coated microneedle-based SERS probe allows direct SERS measurements of analyte molecules in phantoms without the introduction of nanoparticles or the requirement of removing the needle for testing, although at an expense of a reduced AEF due to light absorption and scattering in the phantom layers.…”
Section: Resultssupporting
confidence: 85%
“…Thus, electromagnetic enhancement is resulted for the incident excitation field and the emitted Raman signal for R6G molecules in close vicinity to the Ag surface. The AEF value of 2 Â 10 4 achieved in case of the Ag coated microneedle is comparable to that reported [21] in a different experimental setup in which about an enhancement factor of 10 4 was achieved using a Agcoated tip. Our Ag-coated microneedle-based SERS probe allows direct SERS measurements of analyte molecules in phantoms without the introduction of nanoparticles or the requirement of removing the needle for testing, although at an expense of a reduced AEF due to light absorption and scattering in the phantom layers.…”
Section: Resultssupporting
confidence: 85%
“…TERS has also been attempted in liquids, which would be very beneficial for measuring biological systems in more realistic environments [377]. TERS in liquid may actually solve some problems such as providing a heat-sink for tip-induced sample heating.…”
Section: Applicationsmentioning
confidence: 99%
“…The tip stability over time was not the aim of their studies, however, they showed that SAMs can provide protection against carbon and other tip contaminants. They also determined that the enhancement dropped by approximately a factor of 5 due to the coating [8].…”
Section: Introductionmentioning
confidence: 99%
“…To the best of our knowledge, the Zenobi group [7,8] have provided the only successful report in TERS literature regarding self-assembled monolayers (SAMs) utilized of ethanethiol and thiophenol on the tips. They employed ethanethiol SAMs to protect the surface of a silver probe for TERS in liquid conditions.…”
Section: Introductionmentioning
confidence: 99%