2013
DOI: 10.5370/jeet.2013.8.4.729
|View full text |Cite
|
Sign up to set email alerts
|

Phase Shift Analysis and Phase Identification for Distribution System with 3-Phase Unbalanced Constant Current Loads

Abstract: -Power grids are large complicated networks in use around. An absolute phase value for a particular unknown-phase line at a local site should be identified for the operation and management of a 3-phase distribution network. The phase shift for a specific point in the line, as compared with a phase reference point at a substation, must be within a range of ± 60 o for correct identification. However, the phase shift at a particular point can fluctuate depending on the line constants, transformer wiring method, l… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(9 citation statements)
references
References 4 publications
0
9
0
Order By: Relevance
“…4. More details for the Simulink model such as power sources, lines, unbalanced loads, transformers, grounding resister and phase measurement system for phase simulation are simply explained below [2]. In the first, the input source is expressed in terms of power with an internal resistance and inductance.…”
Section: Simulation and Experimental Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…4. More details for the Simulink model such as power sources, lines, unbalanced loads, transformers, grounding resister and phase measurement system for phase simulation are simply explained below [2]. In the first, the input source is expressed in terms of power with an internal resistance and inductance.…”
Section: Simulation and Experimental Resultsmentioning
confidence: 99%
“…Ku's and Shon's methods cannot discriminate wires of 3-phase distribution lines, instead, it is possible to discriminate transformer served to customers [2,9]. Fig.…”
Section: Narrowband Power Line Communication (N-plc) Is Generally Defmentioning
confidence: 99%
See 2 more Smart Citations
“…As such, most of phase distinguishing methods employ methods that distinguish phases based on comparing the known phase value of a substation with the unknown phase value of a local site [2][3][4][5][6][7]. For the phase determination, GPS technology is utilized to synchronize time at different locations, which is used to measure the phase for electric signals [8].…”
Section: Introductionmentioning
confidence: 99%