2008
DOI: 10.1016/j.desal.2007.01.123
|View full text |Cite
|
Sign up to set email alerts
|

Pilot test of UF pretreatment prior to RO for cooling tower blowdown reuse of power plant

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0
4

Year Published

2013
2013
2021
2021

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 24 publications
(13 citation statements)
references
References 3 publications
0
9
0
4
Order By: Relevance
“…Likewise, its filtrate water quality has also been shown to meet RO and NF feed water quality requirements (Fersi and Dhahbi, 2008;Qin et al, 2003;Uzal et al, 2009;Zhang et al, 2008).…”
Section: Water Recyclingmentioning
confidence: 99%
See 1 more Smart Citation
“…Likewise, its filtrate water quality has also been shown to meet RO and NF feed water quality requirements (Fersi and Dhahbi, 2008;Qin et al, 2003;Uzal et al, 2009;Zhang et al, 2008).…”
Section: Water Recyclingmentioning
confidence: 99%
“…An established wastewater pretreatment technology commonly used in industrial applications is UF. It has been reported to be effective in removing suspended solids and emulsified oils present in industrial wastewater (Karakulski and Morawski, 2000;Norouzbahari et al, 2009;Zhang et al, 2008).…”
Section: Water Recyclingmentioning
confidence: 99%
“…Aufgrund der Komplexität der Kühlwasserzusammensetzung, resultierend aus der Vielzahl eingesetzter Kühlwasserbehandlungschemikalien und produktionsbedingter Stoffeinträge, ist eine Rückgewinnung des Kühlwassers aus der Absalzung mit verfügbaren Verfahren technisch bzw. ökonomisch bislang nicht sinnvoll darstellbar – . Dies gilt insbesondere für Kühlwässer mit direktem Produktkontakt und dem damit verbundenen prozessbedingten Eintrag von Feststoffen (Zunder) und Öl sowie der verwendeten Härtestabilisatoren, Korrosionsschutzmittel, Biozide und teilweise Flockungsmittel.…”
Section: Kühlwässerunclassified
“…Over the past decades, several researchers have studied different methods to reduce the cooling process' fresh water footprint (Altman et al, 2012;Matson & Harris, 1979;Rebhun & Engel, 1988;You, Tseng, Guo, & Yang, 1999;Zhang, Zeng, Ye, Chen, & Yan, 2008). Many of these studies focused on the reuse of CTBD in the cooling tower itself (Frick, F eris, & Tessaro, 2014;Rebhun & Engel, 1988;You et al, 1999;Zhang et al, 2007).…”
Section: Introductionmentioning
confidence: 99%
“…Many of these studies focused on the reuse of CTBD in the cooling tower itself (Frick, F eris, & Tessaro, 2014;Rebhun & Engel, 1988;You et al, 1999;Zhang et al, 2007). Since reuse of CTBD requires electric conductivity (EC) values below 1000 lS/cm , the majority of these studies focused on desalination of CTBD by physicochemical water treatment technologies (Zhang et al, 2008;Altman et al, 2012;van Limpt & van der Wal, 2015;L€ owenberg et al, 2015). Various studies showed that physicochemical CTBD desalination is hampered by conditioning chemicals (CC) that are present in CTBD (Greenlee, Testa, Lawler, Freeman, & Moulin, 2010;L€ owenberg et al, 2015;Sweity, Oren, Ronen, & Herzberg, 2013).…”
Section: Introductionmentioning
confidence: 99%