2005
DOI: 10.1016/j.jpba.2004.08.032
|View full text |Cite
|
Sign up to set email alerts
|

Potentiometric flow injection analysis of mebeverine hydrochloride in serum and urine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
24
0
1

Year Published

2005
2005
2022
2022

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 48 publications
(25 citation statements)
references
References 34 publications
0
24
0
1
Order By: Relevance
“…In previous studies we described a group of ion-exchangerbased PVC membrane electrodes, with liquid inner contact, for the selective determination of dicyclomine [1], mebeverine [2] and drotaverine [3]. The ion-exchanger incorporated in each electrode was an ion-association of the drug cation with the heteropoly anion silicotungstate, silicomolybdate, phosphotungstate or phosphmolybdate.…”
Section: Preliminary Studiesmentioning
confidence: 99%
See 1 more Smart Citation
“…In previous studies we described a group of ion-exchangerbased PVC membrane electrodes, with liquid inner contact, for the selective determination of dicyclomine [1], mebeverine [2] and drotaverine [3]. The ion-exchanger incorporated in each electrode was an ion-association of the drug cation with the heteropoly anion silicotungstate, silicomolybdate, phosphotungstate or phosphmolybdate.…”
Section: Preliminary Studiesmentioning
confidence: 99%
“…Previous work from our laboratory described the development of a group of conventional PVC membrane electrodes for the antispasmodic drugs dicyclomine [1], mebeverine [2] and drotaverine hydrochlorides [3]. The detection limits of these electrodes are in the range of 2 × 10 −6 -8 × 10 −6 M. These moderately high values of detection limits prohibit the use of these electrodes in determination of the drugs in real (unspiked) serum and urine samples.…”
Section: Introductionmentioning
confidence: 99%
“…The ion-exchangers piribedil silicotungstate (PD-ST), piribedil silicomolybdate (PD-SM), piribedil phosphotungstate (PD-PT) and piribedil phosphmolybdate (PD-PM) were prepared as previously described by Ibrahim [27]. The chemical compositions of these compounds were found to be PD 4 ST, PD 4 SM, PD 3 PT, and PD 3 PM as confirmed by (C, H and N) elemental analysis using automatic CHN analyzer (Perkin-Elmer model 2400).…”
Section: Preparation Of Ion-exchangersmentioning
confidence: 99%
“…Previous work from this laboratory described the use of the highly insoluble ion-associates formed from the reactions of heteropoly acids (silicotungstic, silicomolybdic, phosphotungstic and phosphomolybdic) with some organic cations as sensory molecules for a group of ion-selective electrodes [26,27].…”
Section: Introductionmentioning
confidence: 99%
“…They include high performance liquid chromatography (Hoogewijs and Massart, 1986;Stockis et al, 2002), on-line micellar electrokinetic chromatography-mass spectrometry (Somsen et al, 2003), high-performance thin-layer chromatography (De Schutter et al, 1985;El-Walily et al, 1991), capillary supercritical fluid chromatography-mass spectrometry (Pinkston et al, 1993), gas chromatography-mass spectrometry, and online reversed-phase liquid chromatography-gas chromatography (Kristinsson et al, 1994;Tulich et al, 1996;Kraemer et al, 2000). Other alternatives include spectrophotometry (El-Walily et al, 1991;Shama and Amin, 2004) and potentiometric flow injection analysis (Ibrahim et al, 2005).…”
Section: Introductionmentioning
confidence: 99%