1998
DOI: 10.2116/analsci.14.529
|View full text |Cite
|
Sign up to set email alerts
|

Preconcentration of Trace Cadmium from Seawater Using a Dynamically Coated Column of Quaternary Ammonium Salt on C18-Bonded Silica Gel and Determination by Graphite-Furnace Atomic Absorption Spectrometry

Abstract: The determination of trace elements in environmental waters is increasing in contamination studies, owing to the need to guarantee the good quality of water for various purposes. For the determination of Cd in water samples, graphite-furnace atomic absorption spectrometry (GF-AAS) is the chosen method of many analysts because of its relative simplicity, the possibility of automation and the low instrumental detection limits given. However, for complex samples such as seawater, there are important problems: fir… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2000
2000
2011
2011

Publication Types

Select...
3
2
1

Relationship

0
6

Authors

Journals

citations
Cited by 17 publications
(8 citation statements)
references
References 18 publications
0
8
0
Order By: Relevance
“…Thus the rate of Cd recovery from rice foliage seems to increase with increasing concentration of the HCl solution used. However, elevation of the HCl concentration in the extract affects the subsequent process of purification by the chelate column: not only Cd, but also Zn, is trapped in the column 5…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Thus the rate of Cd recovery from rice foliage seems to increase with increasing concentration of the HCl solution used. However, elevation of the HCl concentration in the extract affects the subsequent process of purification by the chelate column: not only Cd, but also Zn, is trapped in the column 5…”
Section: Resultsmentioning
confidence: 99%
“…Cadmium retained in the column was eluted with 5 mL of 0.05 mol L −1 HNO 3 . The column was prepared based on Akatsuka's method 5…”
Section: Methodsmentioning
confidence: 99%
“…5B, Advantec Toyo, Tokyo, Japan), and 1 mL of each filtrate was passed through an ion exchange column (SEP‐01, Sumika Chemical Analysis Service, Osaka, Japan), where Cd was trapped selectively. This column was designed on the basis of Akatsuka et al 's method 8. It is believed that Cd forms a chloro‐complex and is trapped selectively by the column.…”
Section: Methodsmentioning
confidence: 99%
“…With this test, Cd in brown rice was extracted with HCl, and the extract was purified on a chelate silicagel column prepared based on Akatsuka et al 's method8 to remove other metals. The pretreated solution was then diluted with buffer for neutralization and tested with the immunochromatographic assay 6.…”
Section: Introductionmentioning
confidence: 99%
“…Immunochromatography Measurements. For cadmium concentration measurement by immunochromatography, cadmium in HCl extracts was purified by the quaternary ammonium salts employed in a chelating column that was designed on the basis of Akatsuka's method (17 ). Five milliliter HCl extracts of each sample were passed through the chelating column.…”
Section: Methodsmentioning
confidence: 99%