2010
DOI: 10.1016/j.msec.2010.03.023
|View full text |Cite
|
Sign up to set email alerts
|

Preparation, characterization and thermal studies of polymer inclusion cellulose acetate membrane with calix[4]resorcinarenes as carriers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
14
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 36 publications
(16 citation statements)
references
References 38 publications
2
14
0
Order By: Relevance
“…Since the exact mechanism of calixarene-gas interaction is not fully understood, many investigations are continuing in this area [46,47]. Furthermore, calixarene is compatible with CA matrix, and previously it was employed effectively as a carrier in cellulose tri acetate (CTA) membrane for aqueous applications [48,49].…”
Section: Introductionmentioning
confidence: 99%
“…Since the exact mechanism of calixarene-gas interaction is not fully understood, many investigations are continuing in this area [46,47]. Furthermore, calixarene is compatible with CA matrix, and previously it was employed effectively as a carrier in cellulose tri acetate (CTA) membrane for aqueous applications [48,49].…”
Section: Introductionmentioning
confidence: 99%
“…In addition, a band at 1639 cm −1 is attributed to the interlayer stretching and bending vibration modes of molecular water. The characteristic peaks of CA at 1737 (C = O stretching), 1367 (CH 3 symmetric deformation), 1215 (acetate C−C−O stretching), and 1032 (C−O stretching) cm −1 are clearly observed which are generally in accordance with the other literature results . Furthermore, absorptions at 2922 and 1431 cm −1 are attributed to CH 3 asymmetric stretching and CH 3 asymmetric deformation, respectively.…”
Section: Resultsmentioning
confidence: 77%
“…In addition to these, cellulose acetate membrane has a porous physical structure, which helps in the movement of both ions and water molecules toward the sample or in the opposite direction. [31][32][33][34] As seen in Table 2, the concentration of SPS salt immobilised onto the cellulose acetate membrane gives an impression of the response slope when tested at various concentrations of KCl solution and pH of the solution when the solid-state reference electrode was coupled with the standard Ag/AgCl reference electrode with double junction type. In this work, the solid-state reference electrode functioned as a working electrode.…”
Section: Effects Of Sodium Salt Of Poly(anethol Sulfonic Acid)mentioning
confidence: 99%
“…15,16,47 The porous form of cellulose acetate membrane also contributed to the onset of the process of leaching of SPS salts from the cellulose acetate matrix. [29][30][31][32][33][34] From Figure 5, it can be observed that the stability of the solidstate reference electrode was initially low and started to degrade after 35 h.…”
Section: Drift Studymentioning
confidence: 99%