2013
DOI: 10.2214/ajr.12.9737
|View full text |Cite
|
Sign up to set email alerts
|

Prostate Cancer: Comparison of Dynamic Contrast-Enhanced MRI Techniques for Localization of Peripheral Zone Tumor

Abstract: For the experienced reader, sensitivity for peripheral zone tumor was increased by use of either a semiquantitative or quantitative model compared with a qualitative model and decreased by requiring washout. We failed to identify a difference in performance between semiquantitative and quantitative models.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
27
0
1

Year Published

2014
2014
2024
2024

Publication Types

Select...
7
1
1

Relationship

1
8

Authors

Journals

citations
Cited by 54 publications
(32 citation statements)
references
References 28 publications
3
27
0
1
Order By: Relevance
“…Rosenkrantz ve ark. [15], kalitatif analiz yerine semikantitatif veya kantitatif bir yaklaşımın kullanılması ile periferal zonda tümör lokalizasyonunda duyarlılığın arttığını göstermişlerdir [12].…”
Section: Semikantitatif Analiz Ve Zaman -Eğri Analiziunclassified
“…Rosenkrantz ve ark. [15], kalitatif analiz yerine semikantitatif veya kantitatif bir yaklaşımın kullanılması ile periferal zonda tümör lokalizasyonunda duyarlılığın arttığını göstermişlerdir [12].…”
Section: Semikantitatif Analiz Ve Zaman -Eğri Analiziunclassified
“…DCE-MRI should always be interpreted in combination with DWI and T2w imaging which is facilitated by the use of the same slice thicknesses. DCE-MRI significantly increases the accuracy of tumor detection and lesion evaluation and DCE-MRI increases the sensitivity for tumor detection particularly in the peripheral zone [29,30]. A high temporal resolution (at least 9 seconds) is a requirement for being able to measure the rapid enhancement of contrast agent in the prostate [31].…”
Section: Dwi Dce-mri 1 H-mrsmentioning
confidence: 99%
“…However, a high bvalue acquisition reduces the signal from normal prostatic tissue, increasing the sensitivity to abnormal cellular environments [65]. One method of gaining the advantage of contrast of a high b-value while still having the high SNR and fine resolution of a lower b-value acquisition is to extrapolate and compute the theoretical image output for higher b-values [66]. These images show higher SNR than traditional DWI collected with the equivalent high b-values and can be utilized on older 1.5T scanners where gradient hardware may not allow acquisition with high b-values [67].…”
Section: Diffusion-weighted Mr Imagingmentioning
confidence: 99%
“…There are several agents approved by the United States Food and Drug Administration, including gadopentetate dimeglumine (Magnevist), gadobutrol (Gadovist), or gadodiamide (Omniscan) [96]. Aiming for a reasonable spatiotemporal resolution, a five-minute DCE acquisition yields dynamic imaging with a temporal resolution in the range of 3-10 s, a spatial resolution in the range of 0.7 9 0.7 mm to 1.9 9 1.9 mm with a slice thickness of 3-4 mm [27,66,91,92,95,[97][98][99][100][101]. Compressed sensing techniques have been implemented into DCE sequences to improve spatiotemporal resolution or increase the coverage.…”
Section: Dynamic Contrast-enhanced Imagingmentioning
confidence: 99%