2002
DOI: 10.1093/chromsci/40.5.269
|View full text |Cite
|
Sign up to set email alerts
|

Quantitative Analysis Using Directly Coupled Supercritical Fluid Extraction-Capillary Gas Chromatography (SFE-GC) With a Conventional Split/Splitless Injection Port

Abstract: This work presents the carrying out of boiling-point distributions by simulated distillation with direct-column heating rather than oven-column heating. Column-heating rates of 300 degrees C/min are obtained yielding retention times of 73 s for n-tetratetracontane. The calibration curves of the retention time versus the boiling point, in the range of n-pentane to n-tetratetracontane, are identical to those obtained by slower oven-heating rates. The boiling-point distribution of the reference gas oil is compare… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
1
0
1

Year Published

2005
2005
2012
2012

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 1 publication
0
1
0
1
Order By: Relevance
“…Recent articles show that mild approaches for SimDist such as supercritical fluid chromatography , are under study for avoidance of deleterious effects caused by the high temperature set points employed in HTSD . High-speed GCSD is another field of research showing recent interest, with elution of large hydrocarbons such as nC44 having been described in about 70 s, suggesting a dramatic decrease in analysis time for near foreseeable methodologies …”
Section: Introductionmentioning
confidence: 99%
“…Recent articles show that mild approaches for SimDist such as supercritical fluid chromatography , are under study for avoidance of deleterious effects caused by the high temperature set points employed in HTSD . High-speed GCSD is another field of research showing recent interest, with elution of large hydrocarbons such as nC44 having been described in about 70 s, suggesting a dramatic decrease in analysis time for near foreseeable methodologies …”
Section: Introductionmentioning
confidence: 99%
“…Com relação à introdução de amostra, os injetores preferencialmente utilizados para as análises por DS são o injetor na coluna a frio 13,22,36 e o injetor por vaporização com temperatura programável 23,24,37,38 , já que os mesmos diminuem significativamente a discriminação, na agulha, de componentes mais pesados, na transferência da amostra da seringa para o cromatógrafo. Entretanto, o injetor com e sem divisão de fluxo já foi empregado em alguns estudos mais específicos 39,[40][41][42] .…”
Section: Fundamentosunclassified