2012
DOI: 10.1111/j.1365-2842.2012.02343.x
|View full text |Cite
|
Sign up to set email alerts
|

Radiographic evaluation of marginal bone maintenance around tissue level implant and bone level implant: a randomised controlled trial. A 1‐year follow‐up

Abstract: The etiologic factors associated with crestal bone loss have not been comprehensively clarified. Several theories exist as to the reason for the observed changes in crestal bone height following implant restoration. In the 1990s, the wide-diameter implants were commercially introduced. Initially, the implants were restored with standard-diameter abutments because of lack of matching prosthetic components. Long-term radiographic follow-up of these 'platform-switched' restored wide-diameter dental implants has d… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

3
95
1
7

Year Published

2014
2014
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 46 publications
(106 citation statements)
references
References 26 publications
3
95
1
7
Order By: Relevance
“…We could demonstrate that PS reduced peri-implant crestal bone resorption at 1-year post-loading. These results are in accordance with previous clinical studies (Cappiello et al 2008, Fernández-Formoso et al 2012, Telleman et al 2012). This is a 5-year ongoing clinical study and further results are necessary to determine if the concept of PS will show superiority in terms of BLC over time, as suggested by other authors (Astrand et al 2004, Vigolo & Givani 2009).…”
Section: Discussionsupporting
confidence: 94%
“…We could demonstrate that PS reduced peri-implant crestal bone resorption at 1-year post-loading. These results are in accordance with previous clinical studies (Cappiello et al 2008, Fernández-Formoso et al 2012, Telleman et al 2012). This is a 5-year ongoing clinical study and further results are necessary to determine if the concept of PS will show superiority in terms of BLC over time, as suggested by other authors (Astrand et al 2004, Vigolo & Givani 2009).…”
Section: Discussionsupporting
confidence: 94%
“…Effects of platform switching in limiting the peri-implant MBL have been discussed in both prospective and longitudinal human studies (3,9) and displayed long-term stability (15,16). Conversely, numerous studies have also reported results rejecting the platform-switching concept.…”
Section: Discussionmentioning
confidence: 99%
“…16 Dois estudos não especificaram o tipo de exame de imagem utilizado. 23,26 Em relação ao tipo de conexão, a POM variou de 0,04 ± 0,50 para 2,85 ± 0,64 mm para os implantes cone Morse, 14,16,[18][19][20]24 0,33 ± 0,172 para 1,358 ± 0,3939 mm para hexágono interno, 13,15,17 0,66 ±1,21 para hexágono externo 14,25,26 e 0,00 ± 0,37 para 0,30 ± 0,51 mm para conexão interna tri-channel. 22,23 Quanto ao conceito de plataforma switching, a POM variou de 0,04 ± 0,50 e 0,832 ± 0,4427 mm e 0,42 ± 0,11 para 1,358 ± 0,3939 mm para a plataforma convencional.…”
Section: Materiais E Métodosunclassified
“…22,23 Quanto ao conceito de plataforma switching, a POM variou de 0,04 ± 0,50 e 0,832 ± 0,4427 mm e 0,42 ± 0,11 para 1,358 ± 0,3939 mm para a plataforma convencional. 13,17,18,25,26 dIscussão A eliminação ou a redução da POM ao redor de implantes dentários é o objetivo de várias estratégias de modificação do procedimento cirúrgico, alteração da superfície e morfologia do implante, tipo de conexão implante-pilar, entre outros. 18 Implantes instalados ao nível da crista óssea exibiram maiores quantidades de POM abaixo da plataforma comparados com implantes colocados 1 ou 2 mm abaixo do nível da crista óssea.…”
Section: Materiais E Métodosunclassified
See 1 more Smart Citation