2012
DOI: 10.1039/c2jm15717a
|View full text |Cite
|
Sign up to set email alerts
|

Rapid and highly sensitive detection of mercury ions using a fluorescence-based paper test strip with an N-alkylaminopyrazole ligand as a receptor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
36
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 47 publications
(36 citation statements)
references
References 35 publications
0
36
0
Order By: Relevance
“…18,19 The first paper-based sensor was reported in 1883, 20 and since that time the field has evolved from lateral flow assays (1D) 6,21-23 to 3D devices. 16,24-29 Historically, most paper-based assays are implemented using nitrocellulose, 30,31 but the characteristics of this material are best suited for lateral flow sensing rather than multidimensional sensor systems.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…18,19 The first paper-based sensor was reported in 1883, 20 and since that time the field has evolved from lateral flow assays (1D) 6,21-23 to 3D devices. 16,24-29 Historically, most paper-based assays are implemented using nitrocellulose, 30,31 but the characteristics of this material are best suited for lateral flow sensing rather than multidimensional sensor systems.…”
mentioning
confidence: 99%
“…18 Nonetheless, a few groups have successfully developed paper-based sensors that utilize fluorescence detection 16,25 and yield low LODs. 23,44 …”
mentioning
confidence: 99%
“…Several paper monitor sensors have been recently developed for screening contaminants (Alkasir et al 2012) and toxic metals in water (Aragay et al 2012;Ratnarathorn et al 2012). Several paper monitor sensors have been recently developed for screening contaminants (Alkasir et al 2012) and toxic metals in water (Aragay et al 2012;Ratnarathorn et al 2012).…”
Section: Discussionmentioning
confidence: 99%
“…To date, water monitor sensors have been developed for detecting organophosphate and carbamate pesticides (Hossain et al, 2009a), various metals (Hossain and Brennan, 2011;Apilux et al, 2010Apilux et al, , 2012Aragay et al, 2012;Nie et al, 2010;Ratnarathorn et al, 2012), coliform bacteria and phenolic compounds (Alkasir et al, 2012). However, one area where mPAD testing technology is lacking is the existence of simple, quantitative on-site analysis methods that can be performed at low cost by untrained personnel.…”
Section: Introductionmentioning
confidence: 98%