2022
DOI: 10.1016/j.bios.2021.113771
|View full text |Cite
|
Sign up to set email alerts
|

Rapid and simultaneous visual screening of SARS-CoV-2 and influenza virufses with customized isothermal amplification integrated lateral flow strip

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 28 publications
(12 citation statements)
references
References 42 publications
0
12
0
Order By: Relevance
“…In the present study, we developed the RPA-LFD and exo RPA methods for rapid detection of E. miricola . RPA-LFD and exo RPA, which have the advantages of simple operation, sensitive detection and low cost of production, were extensively used in fundamental research and industry [ 18 , 32 , 33 , 35 , 36 ]. However, the RPA method was rarely used in amphibians.…”
Section: Discussionmentioning
confidence: 99%
“…In the present study, we developed the RPA-LFD and exo RPA methods for rapid detection of E. miricola . RPA-LFD and exo RPA, which have the advantages of simple operation, sensitive detection and low cost of production, were extensively used in fundamental research and industry [ 18 , 32 , 33 , 35 , 36 ]. However, the RPA method was rarely used in amphibians.…”
Section: Discussionmentioning
confidence: 99%
“…Such data set outcomes indicated that Ti 3 C 2 -QD-ICA had a high sensitivity and good colorimetric performance for concomitantly detecting H1N1 and SARS-CoV-2 real viruses. The method was compared with other recently reported biosensors in terms of sensitivity, reproducibility, specificity, and assay time in Table S1. ,, Our method demonstrated a relatively superior assay performance among these assays. The Ti 3 C 2 -QD-ICA has the potential to be a valuable POCT instrument focusing upon accurate and rapid clinical determination of respiratory viruses because of its good stability, multiplex detection capability, easy operation, cheap cost, and short detection time.…”
Section: Resultsmentioning
confidence: 99%
“…This is true of isothermal techniques such as the RT-LAMP, which require no thermo-cycler. Thus, RT-LAMP can be combined with an LFA [ 119 ]. In the last few years, LFAs have been adopted for the detection of genetic markers in solution, and advanced into systems that can detect circulating molecules in biological fluids without the need for an instrument.…”
Section: Discussionmentioning
confidence: 99%