2014
DOI: 10.1002/jssc.201400673
|View full text |Cite
|
Sign up to set email alerts
|

Rapid characterization and determination of multiple components in Bu‐Shen‐Yi‐Qi‐Fang by high‐performance liquid chromatography coupled to electrospray ionization and quadrupole time‐of‐flight mass spectrometry

Abstract: In this study, a qualitative and quantitative analysis using high-performance liquid chromatography coupled to electrospray ionization and quadrupole time-of-flight mass spectrometry was performed for the quality control of Bu-Shen-Yi-Qi-Fang, a traditional Chinese formula used for asthma. Thirty-four compounds, including flavonoids, isoflavonoids, triterpenoid saponins, and iridoid glycosides were identified or tentatively characterized by comparing their retention times and mass spectra with those of authent… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 14 publications
(13 citation statements)
references
References 29 publications
0
13
0
Order By: Relevance
“…The flow rate was 0.35 ml/min, and the injection volume was 3  μ L. The MS parameters were as follows: flow rate of drying gas (nitrogen) 10 L/min, nebulizer pressure 30 psig, drying gas temperature (nitrogen) 350°C, and capillary voltage 3500 V. The detection wave length for BSFC was 254 nm. For details, please see our researches [19, 20, 23, 30, 31]. …”
Section: Methodsmentioning
confidence: 99%
“…The flow rate was 0.35 ml/min, and the injection volume was 3  μ L. The MS parameters were as follows: flow rate of drying gas (nitrogen) 10 L/min, nebulizer pressure 30 psig, drying gas temperature (nitrogen) 350°C, and capillary voltage 3500 V. The detection wave length for BSFC was 254 nm. For details, please see our researches [19, 20, 23, 30, 31]. …”
Section: Methodsmentioning
confidence: 99%
“…Q‐TOF‐MS, which provides the elemental composition of detected ions using a combination of high acquisition speeds and accurate mass measurements, is able to provisionally identify unknown compounds . Q‐TOF‐MS instruments also have higher sensitivity than other types of mass spectrometer under full scan mode .…”
Section: Introductionmentioning
confidence: 99%
“…Iridoid glycosides generally contain a glucosyl moiety substituted at the C‐1 position in the pyran ring. Neutral loss of a glucosyl moiety and consecutive losses of H 2 O, CH 3 O, and CO were reported as the fragmentation pathway for the iridoid glycosides .…”
Section: Resultsmentioning
confidence: 99%
“…Its fragment ions displayed at m/z 181 [M–H–Glu] − , 199 [M–H–(Glu‐H 2 O)] − , and 169 [M–H–(Glu‐H 2 O)‐CH 2 O] – were assigned based on some possible fragmentation pathways indicated by the MassFragment software Thus, it was tentatively assigned to be catalpol. Similarly, other iridoid glycosides were tentatively assigned on the basis of characteristic fragment ions and literature reports .…”
Section: Resultsmentioning
confidence: 99%