1986
DOI: 10.1107/s0021889886089008
|View full text |Cite
|
Sign up to set email alerts
|

Rapid collection of X-ray powder data for pattern analysis by a cylindrical position-sensitive detector

Abstract: An apparatus has been developed which permits rapid collection of X‐ray powder diffraction data for structure refinement by pattern analysis. The apparatus is built on a cylindrical position‐sensitive detector with an angular aperture of 120° and resolution of 0.05° in 2θ. The detector uses a metal blade as anode and works in the self‐quenching streamer mode of gas ionization. A wide‐angle powder pattern can be recorded simultaneously from a stationary specimen, where geometrical broadening of reflection lines… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
6
0

Year Published

1989
1989
2009
2009

Publication Types

Select...
8
1
1

Relationship

0
10

Authors

Journals

citations
Cited by 17 publications
(6 citation statements)
references
References 3 publications
0
6
0
Order By: Relevance
“…Both the stable γ -Bi 12 SiO 20 and the metastable δ-Bi 12 SiO 20 could be directly solidified from the stoichiometric melt of 6Bi 2 O 3 • SiO 2 (namely Bi 12 SiO 20 if the reaction has proceeded to completion) [8]. The nomenclatures for Bi 12 SiO 20 were taken from the polymorphism of Bi 2 O 3 , α-Bi 2 O 3 (monoclinic), β-Bi 2 O 3 (tetragonal), γ -Bi 2 O 3 (BCC) and δ-Bi 2 O 3 (FCC) [7,[9][10][11][12][13][14][15]. However, literature sources on the phase transitions of Bi 12 SiO 20 are relatively few.…”
Section: Introductionmentioning
confidence: 99%
“…Both the stable γ -Bi 12 SiO 20 and the metastable δ-Bi 12 SiO 20 could be directly solidified from the stoichiometric melt of 6Bi 2 O 3 • SiO 2 (namely Bi 12 SiO 20 if the reaction has proceeded to completion) [8]. The nomenclatures for Bi 12 SiO 20 were taken from the polymorphism of Bi 2 O 3 , α-Bi 2 O 3 (monoclinic), β-Bi 2 O 3 (tetragonal), γ -Bi 2 O 3 (BCC) and δ-Bi 2 O 3 (FCC) [7,[9][10][11][12][13][14][15]. However, literature sources on the phase transitions of Bi 12 SiO 20 are relatively few.…”
Section: Introductionmentioning
confidence: 99%
“…Structure refinements by the Rietveld method from data collected by means of a curved PSD have also been reported (e.g. Shishiguchi, Minato & Hashizume, 1986;St~.hl & Thomasson, 1992). Although the quality of the uniformity of the response over its angular range required special attention, a reasonable accuracy in the results was obtained.…”
Section: Introductionmentioning
confidence: 90%
“…Furthermore, the advent of synchrotron X-ray sources has propelled the need to develop X-ray detectors to conduct dynamic studies in real time (Hall & Lewis, 1994). Amongst the various detector systems which have been considered in the past are (i) multi-detector systems (Fitch, 2004;Lee et al, 2008) and (ii) position-sensitive detectors (PSDs), which include linear sensitive proportional counters (Evain et al, 1993;Shishiguchi et al, 1986;Wö lfel, 1983), charge coupled devices (i.e. CCDs) and image-plate (IP) systems (Amemiya, 1995;Norby, 1997;Stå hl, 2000).…”
Section: Introductionmentioning
confidence: 99%