2013
DOI: 10.1016/j.snb.2012.11.011
|View full text |Cite
|
Sign up to set email alerts
|

Rapid monitoring of CFP-10 during culture of Mycobacterium tuberculosis by using a magnetophoretic immunoassay

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
20
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
9
1

Relationship

4
6

Authors

Journals

citations
Cited by 32 publications
(20 citation statements)
references
References 22 publications
0
20
0
Order By: Relevance
“…These processes are highly sensitive, but time -consuming technique since it requires over 10 days for TB diagnosis. 32 To make it worse, these techniques are not suitable to distinguish mycobacterium tuberculosis (MTB) and nontuberculous mycobacteria (NTM). 33 Thus, in order to overcome these disadvantages, many different TB sensing systems have been developed to show rapid detection, and high sensitivity and selectivity using direct clues, e.g., secreted antigens of TB virus such as CFP-10 biomarker.…”
Section: Resultsmentioning
confidence: 99%
“…These processes are highly sensitive, but time -consuming technique since it requires over 10 days for TB diagnosis. 32 To make it worse, these techniques are not suitable to distinguish mycobacterium tuberculosis (MTB) and nontuberculous mycobacteria (NTM). 33 Thus, in order to overcome these disadvantages, many different TB sensing systems have been developed to show rapid detection, and high sensitivity and selectivity using direct clues, e.g., secreted antigens of TB virus such as CFP-10 biomarker.…”
Section: Resultsmentioning
confidence: 99%
“…3 The sandwichtype of immunoassay is popular since it is based on nanomaterials substrates. [4][5][6][7] Recently, multiplex immunoassay using nanomaterials have attracted significant interest. [8][9][10][11][12] Especially, SERS-fluorescence dual mode nanoprobes were expected to improve the imaging quality and detection sensitivity of the fluorescence signal, quick indicator; meanwhile SERS could help to distinguish specific targets in multiplex interactions.…”
Section: Introductionmentioning
confidence: 99%
“…Their functionalization with different reactive groups, especially antibodies, makes them useful to bind and pre-concentrate a variety of targets under magnetic actuation, through immunomagnetic separation. Moreover, the pre-concentration of the target from the complex sample is easily achieved, offering an attractive technology to be implemented in magneto-actuated platforms including biosensors [10], microfluidic platforms [11], among others [12].…”
Section: Introductionmentioning
confidence: 99%